{"product_id":"w638","title":"W638, 145THTN19079, 1 Hp, 1200 Rpm, 145T FR, 575 Vac, 3 PH, TENV, Rigid Base, Severe Duty Motor","description":"\u003cp\u003eW638, 145THTN19079, 1 Hp, 1200 Rpm, 145T FR, 575 Vac, 3 PH, TENV, Rigid Base, Severe Duty Motor.\u003c\/p\u003e\n\n\u003cp\u003eEngineering Data\u003cbr\u003e\n60 Hertz\u003cbr\u003e\nHP\t1\tVoltage\t575\u003cbr\u003e\nkW\t0.75\tFL Amps\t1.3\u003cbr\u003e\nRPM\t1200\t\t\u003cbr\u003e\nFL Eff\t80 %\tSF\t1.15\u003c\/p\u003e\n\n\u003cp\u003ePhase\t3\tInsulation Class\tF\u003cbr\u003e\nFrame\t145T\tDuty\tCONTINUOUS\u003cbr\u003e\nEnclosure\tTENV\tAmbient\t40\u003cbr\u003e\nMounting\tRigid\tNEMA Design\tB\u003cbr\u003e\nOrientation\tHORIZONTAL\tStarting Type\tLINE OR INVERTER\u003cbr\u003e\nAssembly\tF1 (F2 Modification Available)\tKVA Code\tJ\u003cbr\u003e\nDrive End Bearing\tBALL\tIP Code\t56\u003cbr\u003e\nOpposite End Bearing\tBALL\t\t\u003cbr\u003e\nDrive End Bearing Size\t6205\t\t\u003cbr\u003e\nOpposite End Bearing Size\t6203\tHazardous Location\tDIVISION 2 T2B\u003cbr\u003e\nWeight\t60 LB lbs\tInverter Speed Range\tCONSTANT 10:1\u003cbr\u003e\nCE\tY\tCSA\tY\u003cbr\u003e\nUL\tRecognized Construction\u003cbr\u003e\nThermal Protection\tNone\u003c\/p\u003e","brand":"Industrial Motors","offers":[{"title":"Default Title","offer_id":51663239840066,"sku":"W638","price":1101.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/2298\/4002\/files\/rigid_base_2_208_1_1_1_1.jpg?v=1766407252","url":"https:\/\/industrialmotors.com\/products\/w638","provider":"Industrial Motors","version":"1.0","type":"link"}