Industrial Motors
Couldn't load pickup availability
171586.60, 15 HP, 3600 RPM, 254TC FR, TEFC, 208-230/460 Vac, 3 PH, C Face w/Base, General Purpose.
Engineering Data
Volts 208-230 Volts 460 Volts 190/380
F.L. Amps 38-34.5 F.L. Amps 17.3 F.L. Amps 22/11
S. F Amps 48.5-44 S. F Amps 22 S. F Amps 28/14
RPM 3600 Hertz 60/50
HP 15 Duty CONTINUOUS TYPE TF
KW 11.2
Frame 254TC Serv. Factor 1.25 Phase 3
Max Amb 40 Design B Code G
Insul Class F Protection NOT Therm.Prot.
Eff 100% 92.4 Eff 75% PF 88.5
UL V-INS, CONST UL REC CSA No Bearing OPE 6308
CC Number CC005A CE No Bearing PE 6309
Load Type Inverter Type Speed Range NONE
Motor Wt. 292 LB Enclosure TEFC Lubrication POLYREX EM
Nameplate Mounting RIGID Rotation REV
Assembly Shaft Dia. Ext. Diag. 004172.01
Cust Part No Outline SS622044LE Ext. Diag2
Packaging B Winding T12902021
Carton Label GROUP: 3
Iris Paint LEESON WATTSAVER GREEN Test Card
Form Factor RMS Amps Const Torque Speed Range
Torque Peak
AB Code Peak@DegC
Resistance
Connection
Rework Status Rework TYPE
Hazardous Loc NONE Brake Motors
Explosion Proof Temp Op Code FORCE
Class GROUP: VDC
Class GROUP: ADC
Brake Coil OHMs @25 C
Performance
Torque UOM Inertia (WK²)
Torque
CURRENT (amps)
Efficiency (%)
PowerFactor
Load Curve Data @60/50 Hz, 460 Volts, 15 Horsepower
Load Amps KW RPM Torque EFF PF Rise By Resis Frame Rise
0.0 4.9 0.3 3600 0.0 0.0 8.3 0.0 -
0.25 6.8 3.3 3590 5.6 87.5 60.5 0.0 -
0.5 9.9 6.3 3577 11.3 91.7 79.0 0.0 -
0.75 13.7 9.3 3563 17.0 92.4 85.0 0.0 -
1.0 17.3 12.3 3550 22.2 92.4 88.5 50.0 -
1.15 20.5 14.0 3540 25.5 91.7 88.0 70.0 -
1.25 22.0 15.3 3535 28.0 91.0 87.5 85.0 -
SOURCE: CALCULATED GROUP: 3