Industrial Motors
Couldn't load pickup availability
100001.00, 1/3 Hp, 1800 Rpm, 56 FR, DP, 115/208-230 Vac, 1 PH, Rigid Base, Capacitor Start, General Purpose.
Engineering Data
Volts 115 Volts 208-230 Volts
F.L. Amps 6.6 F.L. Amps 2.9-3.3 F.L. Amps
S. F Amps 7.2 S. F Amps 3.4-3.6 S. F Amps
RPM 1800 Hertz 60
HP .33 Duty CONTINUOUS TYPE CD
KW
Frame S56 Serv. Factor 1.35 Phase 1
Max Amb 40 Design N Code L
Insul Class B Protection AUTOMATIC Therm.Prot. CEG69GV
Eff 100% 61 Eff 75% PF 59
UL Y-(LEESON UL REC) CSA Yes Bearing OPE 6203
CC Number CE Bearing PE 6203
Load Type Inverter Type Speed Range NONE
Motor Wt. 16 LB Enclosure DP Lubrication STANDARD
Nameplate A-92005-6 Mounting RIGID Rotation SELECTIVE CCW
Assembly LO100001 Shaft Dia. 5/8 IN Ext. Diag. 005003.52
Cust Part No Outline 031619-525 Ext. Diag2
Packaging B Outline Dash No Winding CE484205
Carton Label Leeson Gen Purpose GROUP : 3
Iris Paint BLUE - LEESON (ENAMEL) Test Card
Form Factor RMS Amps Const Torque Speed Range
Torque Peak
AB Code Peak@DegC
Resistance
Connection
Rework Status Rework TYPE
Hazardous Loc NONE Brake Motors
Explosion Proof Temp Op Code FORCE
Class GROUP : VDC
Class GROUP : ADC
Brake Coil OHMs @25 C
Performance
Torque UOM OZ-FT Inertia (WK²) -1 LB-FT^2
Torque 16(Full Load) 38(Break Down) 35.7(Pull Up) 51.1(Locked Rotor)
CURRENT (amps) 3.3(Full Load) 0(Break Down) 0(Pull Up) 14(Locked Rotor)
Efficiency (%) 0(Full Load) 54.9(75% Load) 46.5(50% Load) 30.6(25% Load)
PowerFactor (Full Load) 47.5(75% Load) 38.9(50% Load) 30.2(25% Load)
Load Curve Data @60 Hz , NONE Volts , .33 Horsepower
Load Amps KW2 RPM Torque EFF PF Rise By Resis Frame Rise
0.0 3.0 0.144 1787 0.0 0.0 20.9 0.0 -
0.25 2.98 0.207 1785 4.0 30.6 30.2 0.0 -
0.5 3.03 0.271 1774 8.0 46.5 38.9 0.0 -
0.75 3.13 0.342 1762 12.0 54.9 47.5 0.0 -
1.0 3.28 0.414 1749 16.0 60.0 54.9 43.6 -
1.25 3.49 0.494 1734 20.0 62.3 61.5 0.0 -
1.35 3.6 0.54 1715 21.6 61.0 65.0 0.0 -
1.5 3.76 0.579 1719 24.0 63.3 67.0 0.0 -