Industrial Motors
Couldn't load pickup availability
**This motor is no longer available, possible replacement is Model# 10119.00, 60 HZ Motor**
101644.00, 3/4 HP, 1800 RPM, 48YZ FR, TEFC, 110/220 Vac, 1 PH, TEFC, C-Face Less Base, 50 Hertz, Feed-Auger Drive Motor
Engineering Data
Volts 110 Volts 220 Volts
F.L. Amps 11.6 F.L. Amps 5.8 F.L. Amps
S. F Amps None S. F Amps S. F Amps
RPM 1500 Hertz 50
HP 3/4 Duty CONTINUOUS TYPE CF
KW 0.56
Frame 48Y Serv. Factor 1.0 Phase 1
Max Amb 40 Design NO DESIGN CODE Code K
Insul Class F Protection MANUAL Therm.Prot. CEJ65CB
Eff 100% 69 Eff 75% PF 64
UL Y-(LEESON UL REC) CSA Yes Bearing OPE 6203
CC Number EXEMPT CE No Bearing PE 6203
Load Type Inverter Type NONE Speed Range NONE
Motor Wt. 33 LB Enclosure TEFC Lubrication STANDARD
Nameplate A-92005-6 Mounting VERIFY Rotation SELECTIVE CCW
Assembly LO101644 Shaft Dia. 1/2 IN Ext. Diag. 005003.72
Cust Part No Outline 031779-775 Ext. Diag2
Packaging B Winding CE484271
Carton Label Leeson Farm Duty GROUP: 3
Iris Paint RED - LEESON (POWDER) Test Card
Form Factor RMS Amps Const Torque Speed Range
Torque Peak
AB Code Peak@DegC
Resistance
Connection
Rework Status Rework TYPE
Hazardous Loc NONE Brake Motors
Explosion Proof Temp Op Code FORCE
Class GROUP: VDC
Class GROUP: ADC
Brake Coil OHMs @25 C
Performance
Torque UOM OZ-FT Inertia (WK²) -1 LB-FT^2
Torque 43.5(Full Load) 110(Break Down) 101.8(Pull Up) 130(Locked Rotor)
CURRENT (amps) 5.8(Full Load) 0(Break Down) 0(Pull Up) 27(Locked Rotor)
Efficiency (%) 0(Full Load) 66.2(75% Load) 59.8(50% Load) 44.7(25% Load)
PowerFactor (Full Load) 55.3(75% Load) 44.3(50% Load) 31.4(25% Load)
Load Curve Data @50 Hz, 220 Volts, 3/4 Horsepower
Load Amps KW RPM Torque EFF PF Rise By Resis Frame Rise
0.0 4.55 0.171 1496 0.0 0.0 17.1 0.0 -
0.25 4.58 0.316 1488 10.7 44.7 31.4 0.0 -
0.5 4.81 0.469 1476 21.4 59.8 44.3 0.0 -
0.75 5.22 0.635 1466 32.3 66.2 55.3 0.0 -
1.0 5.79 0.816 1452 43.5 68.7 64.1 95.0 -
1.25 6.55 1.019 1435 55.0 68.8 70.7 0.0 -
1.5 7.52 1.247 1416 66.8 67.4 75.4 0.0 -