Industrial Motors
Couldn't load pickup availability
113266.00, 1 1/2 HP, 1800 RPM, 56H FR, 115/208-230 Vac, 1 PH, DP, Rigid Base, Pressure Washer Pump
Engineering Data
Volts 115 Volts 208-230 Volts
F.L. Amps 13.4 F.L. Amps 6.7 F.L. Amps
S. F Amps 15.2 S. F Amps 7.6 S. F Amps
RPM 1800 Hertz 60
HP 1.5 Duty CONTINUOUS TYPE KD
KW 1.12
Frame 56H Serv. Factor 1.15 Phase 1
Max Amb 40 Design NO DESIGN CODE Code H
Insul Class B Protection MANUAL Therm.Prot. CEJ50CB
Eff 100% 81.5 Eff 75% PF 89
UL Y-(LEESON UL REC) CSA Yes Bearing OPE 6203
CC Number CE No Bearing PE 6203
Load Type Inverter Type Speed Range NONE
Motor Wt. 45 LB Enclosure DP Lubrication POLYREX EM
Nameplate 004004 Mounting RIGID Rotation SELECTIVE CCW
Assembly Shaft Dia. 5/8 IN Ext. Diag. 005053.01
Cust Part No Outline 032658-750 Ext. Diag2
Packaging B Winding K634315
Carton Label Leeson Gen Purpose GROUP: 3
Iris Paint STANDARD Test Card 01
Form Factor RMS Amps Const Torque Speed Range
Torque Peak
AB Code Peak@DegC
Resistance
Connection
Rework Status Rework TYPE
Hazardous Loc NONE Brake Motors
Explosion Proof Temp Op Code FORCE
Class GROUP: VDC
Class GROUP: ADC
Brake Coil OHMs @25 C
Performance
Torque UOM LB-FT Inertia (WK²) .14 LB-FT^2
Torque 4.5(Full Load) 11(Break Down) 9.33(Pull Up) 12.46(Locked Rotor)
CURRENT (amps) 6.69(Full Load) 23(Break Down) 31.1(Pull Up) 46(Locked Rotor)
Efficiency (%) 0(Full Load) 80.3(75% Load) 74.9(50% Load) 60.8(25% Load)
PowerFactor 0(Full Load) 84.5(75% Load) 77.1(50% Load) 62.5(25% Load)
Load Curve Data @60 Hz, 230 Volts, 1.5 Horsepower
Load Amps KW RPM Torque EFF PF Rise By Resis Frame Rise
0.0 2.8 0.26 1796 0.0 0.0 40.4 0.0 -
0.25 3.2 0.46 1789 1.1 60.8 62.5 0.0 -
0.5 4.2 0.745 1778 2.21 74.9 77.1 0.0 -
0.75 5.4 1.05 1767 3.36 80.3 84.5 0.0 -
1.0 6.69 1.37 1750 4.5 81.6 89.0 0.0 -
1.25 8.38 1.734 1733 5.71 81.1 90.0 0.0 -
1.5 10.17 2.13 1713 6.9 78.8 91.1 0.0 -