Industrial Motors
Couldn't load pickup availability
113373.00, 1-0.44 HP, 1725 PRM, 56H FR, 230 Vac, 1 PH, DP, Resilient Base, Fan & Blower.
Engineering Data
Volts 230 Volts Volts 230
F.L. Amps 6.5 F.L. Amps F.L. Amps 4.6
S. F Amps S. F Amps S. F Amps
RPM 1800 Hertz 60/60
HP 1 Duty CONTINUOUS TYPE KD
KW 0.75
Frame 56H Serv. Factor 1.0 Phase 1
Max Amb 40 Design NO DESIGN CODE Code K
Insul Class F Protection NOT Therm.Prot.
Eff 100% Eff 75% PF
UL Yes CSA Yes Bearing OPE 6203
CC Number CE Bearing PE 6203
Load Type Inverter Type Speed Range NONE
Motor Wt. 42 LB Enclosure DP Lubrication POLYREX EM
Nameplate 004001 Mounting RESILIENT BASE Rotation SELECTIVE CCW
Assembly 042506 Shaft Dia. 5/8 IN Ext. Diag. 005228.01
Cust Part No Outline 028757-700B Ext. Diag2
Packaging B Winding K63(4-6)15
Carton Label Leeson Fan And Blower GROUP: 2
Iris Paint STANDARD Test Card 01
Form Factor RMS Amps Const Torque Speed Range
Torque Peak
AB Code Peak@DegC
Resistance
Connection
Rework Status Rework TYPE
Hazardous Loc NONE Brake Motors
Explosion Proof Temp Op Code FORCE
Class GROUP: VDC
Class GROUP: ADC
Brake Coil OHMs @25 C
Performance
Torque UOM LB-FT Inertia (WK²) .135 LB-FT^2
Torque 3(Full Load) 8.6(Break Down) 5.9(Pull Up) 6.8(Locked Rotor)
CURRENT (amps) 6.06(Full Load) 0(Break Down) 0(Pull Up) 39(Locked Rotor)
Efficiency (%) 0(Full Load) 65.8(75% Load) 58(50% Load) 41.3(25% Load)
PowerFactor 0(Full Load) 69.6(75% Load) 58.7(50% Load) 44.5(25% Load)
Load Curve Data @60/60 Hz, 230 Volts, 1 Horsepower
Load Amps KW RPM Torque EFF PF Rise By Resis Frame Rise
0.0 4.35 0.276 1798 0.0 0.0 27.6 0.0 -
0.25 4.4 0.45 1791 0.73 41.3 44.5 0.0 -
0.5 4.75 0.641 1782 1.47 58.0 58.7 0.0 -
0.75 5.3 0.849 1772 2.22 65.8 69.6 0.0 -
1.0 6.06 1.079 1760 3.0 69.5 77.4 62.0 -
1.25 7.03 1.341 1747 3.75 69.4 82.9 0.0 -
1.5 8.27 1.845 1729 4.62 61.5 97.0 0.0 -