Industrial Motors
Couldn't load pickup availability
117907.00, 3/4 HP, 1800 Rpm, 56C FR, TEFC, 208-230/460 Vac, 3 PH,C-Face with Base, Stainless & Encapsulated Motor with Shaft Grounding Ring.
Engineering Data
Volts 208-230 Volts 460 Volts 190/380
F.L. Amps 2.4-2.3 F.L. Amps 1.15 F.L. Amps 1.8/.9
S. F Amps 2.7-2.5 S. F Amps 1.25 S. F Amps 2/1
RPM 1800 Hertz 60/50
HP 3/4 Duty CONTINUOUS TYPE TN
KW 0.56
Frame 56C Serv. Factor 1.15 Phase 3
Max Amb 40 Design B Code L
Insul Class F Protection NOT Therm.Prot.
Eff 100% 80 Eff 75% PF 76
UL Y-(LEESON UL REC) CSA Yes Bearing OPE 6205
CC Number EXEMPT CE Yes Bearing PE 6205
Load Type Inverter Type Speed Range NONE
Motor Wt. 45 LB Enclosure TENV Lubrication POLYREX EM
Nameplate 213-0016 Mounting RIGID Rotation REV
Assembly 042541 Shaft Dia. 5/8 IN Ext. Diag. 005010.52
Cust Part No Outline 028767-625 Ext. Diag2
Packaging B Winding T634252
Carton Label Leeson Stainless Washguard GROUP: 3
Iris Paint NO PAINT Test Card 03
Form Factor RMS Amps Const Torque Speed Range
Torque Peak
AB Code Peak@DegC
Resistance
Connection
Rework Status Rework TYPE
Hazardous Loc NONE Brake Motors
Explosion Proof Temp Op Code FORCE
Class GROUP: VDC
Class GROUP: ADC
Brake Coil OHMs @25 C
Performance
Torque UOM OZ-FT Inertia (WK²) .108 LB-FT^2
Torque 36(Full Load) 148.8(Break Down) 104.3(Pull Up) 110.6(Locked Rotor)
CURRENT (amps) 1.12(Full Load) 5.5(Break Down) 9.1(Pull Up) 9.14(Locked Rotor)
Efficiency (%) 0(Full Load) 79.1(75% Load) 74.5(50% Load) 62(25% Load)
PowerFactor 0(Full Load) 70.5(75% Load) 59.4(50% Load) 42.1(25% Load)
Load Curve Data @60/50 Hz, 460 Volts, 3/4 Horsepower
Load Amps KW RPM Torque EFF PF Rise By Resis Frame Rise
0.0 0.62 0.084 1794 0.0 0.0 17.0 0.0 -
0.25 0.68 0.228 1788 8.9 62.0 42.1 0.0 -
0.5 0.79 0.376 1777 17.8 74.5 59.4 0.0 -
0.75 0.94 0.531 1765 26.8 79.1 70.5 0.0 -
1.0 1.12 0.689 1753 36.0 81.2 77.3 82.0 -
1.25 1.32 0.858 1740 45.3 81.5 81.8 0.0 -
1.5 1.54 1.036 1725 54.8 81.0 84.6 0.0 -
1.75 1.78 1.222 1709 64.6 80.1 86.2 0.0 -
2.0 2.05 1.427 1689 74.7 78.4 87.2 0.0 -