Industrial Motors
Couldn't load pickup availability
121060.00, 3 HP, 3600 RPM, 145TC FR, TEFC, 230 Vac, 1 PH, C Face w/Base, General Purpose
Engineering Data
Volts 230 Volts Volts
F.L. Amps 13 F.L. Amps F.L. Amps
S. F Amps None S. F Amps S. F Amps
RPM 3600 Hertz 60
HP 3 Duty CONTINUOUS TYPE KF
KW 2.24
Frame 145TC Serv. Factor 1.0 Phase 1
Max Amb 40 Design L Code J
Insul Class F Protection MANUAL Therm.Prot. BRJ42DB
Eff 100% 81.5 Eff 75% PF 91
UL No CSA No Bearing OPE 6203
CC Number NONE CE No Bearing PE 6205
Load Type Inverter Type Speed Range NONE
Motor Wt. 54 LB Enclosure TEFC Lubrication POLYREX EM
Nameplate 993500 Mounting RIGID Rotation SELECTIVE CCW
Assembly Shaft Dia. 7/8 IN Ext. Diag. 005056.03
Cust Part No Outline 028804-850C Ext. Diag2
Packaging B Winding K632129
Carton Label Leeson Gen Purpose GROUP: 2
Iris Paint STANDARD Test Card 01
Form Factor RMS Amps Const Torque Speed Range
Torque Peak
AB Code Peak@DegC
Resistance
Connection
Rework Status Rework TYPE
Hazardous Loc NONE Brake Motors
Explosion Proof Temp Op Code FORCE
Class GROUP: VDC
Class GROUP: ADC
Brake Coil OHMs @25 C
Performance
Torque UOM LB-FT Inertia (WK²) .1 LB-FT^2
Torque 4.5(Full Load) 13.5(Break Down) 12.9(Pull Up) 13.6(Locked Rotor)
CURRENT (amps) 13(Full Load) 0(Break Down) 0(Pull Up) 100(Locked Rotor)
Efficiency (%) 0(Full Load) 81.3(75% Load) 77.4(50% Load) 64(25% Load)
PowerFactor (Full Load) 88.2(75% Load) 81(50% Load) 67.4(25% Load)
Load Curve Data @60 Hz, 230 Volts, 3 Horsepower
Load Amps KW RPM Torque EFF PF Rise By Resis Frame Rise
0.0 4.73 0.341 3598 0.0 0.0 31.3 0.0 -
0.25 5.79 0.897 3577 1.13 64.0 67.4 0.0 -
0.5 7.89 1.47 3557 2.25 77.4 81.0 0.0 -
0.75 10.3 2.089 3536 3.38 81.3 88.2 0.0 -
1.0 13.03 2.726 3512 4.5 82.4 91.0 80.0 -
1.25 15.94 3.397 3486 5.63 82.1 92.7 0.0 -
1.5 19.08 4.1 3455 6.75 80.8 93.4 0.0 -
SOURCE: CALCULATED GROUP: 2