Industrial Motors
Couldn't load pickup availability
** This motor has been replaced by Model # 120922.00 **
121099.00, 1 1/2 Hp, 1800 Rpm, 145T FR, 208-230/460 Vac, 3 PH, TENV, Rigid Base, Compressor Duty Motor
Engineering Data
Volts 208-230 Volts 460 Volts
F.L. Amps 4.2 F.L. Amps 2.1 F.L. Amps
S. F Amps 4.6 S. F Amps 2.3 S. F Amps
RPM 1800 Hertz 60
HP 1 1/2 Duty CONTINUOUS TYPE TN
KW 1.12
Frame J145T Serv. Factor 1.15 Phase 3
Max Amb 40 Design B Code K
Insul Class F Protection NOT Therm.Prot.
Eff 100% 84 Eff 75% PF 80
UL Yes CSA Yes Bearing OPE 6203
CC Number CE No Bearing PE 6205
Load Type Inverter Type Speed Range NONE
Motor Wt. 50 LB Enclosure TENV Lubrication POLYREX EM
Nameplate 004002 Mounting RIGID Rotation REV
Assembly Shaft Dia. 7/8 IN Ext. Diag. 005010.01
Cust Part No Outline 034983-800 Ext. Diag2
Packaging B Winding T634244
Carton Label Leeson Gen Purpose GROUP: 3
Iris Paint STANDARD Test Card 02
Form Factor RMS Amps Const Torque Speed Range
Torque Peak
AB Code Peak@DegC
Resistance
Connection
Rework Status Rework TYPE
Hazardous Loc NONE Brake Motors
Explosion Proof Temp Op Code FORCE
Class GROUP: VDC
Class GROUP: ADC
Brake Coil OHMs @25 C
Performance
Torque UOM LB-FT Inertia (WK²) .162 LB-FT^2
Torque 4.5(Full Load) 17(Break Down) 14.2(Pull Up) 15.1(Locked Rotor)
CURRENT (amps) 4.2(Full Load) 0(Break Down) 0(Pull Up) 33.6(Locked Rotor)
Efficiency (%) 0(Full Load) 85(75% Load) 84(50% Load) 79.1(25% Load)
PowerFactor (Full Load) 72.1(75% Load) 60(50% Load) 40(25% Load)
Load Curve Data @60 Hz, 460 Volts, 1 1/2 Horsepower
Load Amps KW RPM Torque EFF PF Rise By Resis Frame Rise
0.0 2.05 0.07 1799 0.0 0.0 8.5 0.0 -
0.25 2.28 0.363 1789 1.13 79.1 40.0 0.0 -
0.5 2.83 0.676 1777 2.25 84.0 60.0 0.0 -
0.75 3.47 0.997 1764 3.38 85.0 72.1 0.0 -
1.0 4.18 1.332 1750 4.5 84.0 80.0 95.0 -
1.25 5.02 1.655 1734 5.63 83.8 82.8 0.0 -
1.5 5.95 2.01 1717 6.75 81.9 84.8 0.0 -