Engineering Data
Volts 115 Volts 208-230 Volts
F.L. Amps 14 F.L. Amps 7 F.L. Amps
S. F Amps 15 S. F Amps 7.5 S. F Amps
RPM 1800 Hertz 60
HP 1 Duty CONTINUOUS TYPE CF
KW 0.75
Frame 143T Serv. Factor 1.15 Phase 1
Max Amb 40 Design N Code K
Insul Class B Protection MANUAL Therm.Prot. CED2797
Eff 100% 74 Eff 75% PF 63
UL Y-(LEESON UL REC) CSA Yes Bearing OPE 6203
CC Number EXEMPT CE No Bearing PE 6205
Load Type Inverter Type Speed Range NONE
Motor Wt. 33 LB Enclosure TEFC Lubrication POLYREX EM
Nameplate 993500 Mounting RIGID Rotation SELECTIVE CCW
Assembly Shaft Dia. 7/8 IN Ext. Diag. 005003.03
Cust Part No Outline 028915-700 Ext. Diag2
Packaging B Winding C634259
Carton Label Leeson Farm Duty GROUP: 3
Iris Paint RED - LEESON FARM DUTY Test Card 04
Form Factor RMS Amps Const Torque Speed Range
Torque Peak
AB Code Peak@DegC
Resistance
Connection
Rework Status Rework TYPE
Hazardous Loc NONE Brake Motors
Explosion Proof Temp Op Code FORCE
Class GROUP: VDC
Class GROUP: ADC
Brake Coil OHMs @25 C
Performance
Torque UOM OZ-FT Inertia (WK²) .099 LB-FT^2
Torque 48.16(Full Load) 132.6(Break Down) 117.6(Pull Up) 141.8(Locked Rotor)
CURRENT (amps) 7.01(Full Load) 17.9(Break Down) 29(Pull Up) 37.3(Locked Rotor)
Efficiency (%) 0(Full Load) 67.8(75% Load) 61.6(50% Load) 46.6(25% Load)
PowerFactor 0(Full Load) 57.8(75% Load) 46.9(50% Load) 33.3(25% Load)
Load Curve Data @60 Hz, 230 Volts, 1 Horsepower
Load Amps KW RPM Torque EFF PF Rise By Resis Frame Rise
0.0 4.85 0.206 1797 0.0 0.0 0.0 0.0 -
0.25 5.24 0.401 1787 11.74 46.6 33.3 0.0 -
0.5 5.61 0.606 1776 23.67 61.6 46.9 0.0 -
0.75 6.2 0.825 1764 35.74 67.8 57.8 0.0 -
1.0 7.01 1.063 1751 48.16 70.4 65.9 88.6 47.2
1.15 7.56 1.208 1743 55.44 71.0 69.4 102.0 56.3
1.25 7.97 1.312 1738 60.47 71.1 71.5 0.0 -
1.5 9.14 1.586 1722 73.28 70.6 75.5 0.0 -