131544.00, 3 HP, 1800 RPM, 184TC FR, DP, 115/208-230 Vac, 1 PH, C Face Less Base, General Purpose
Engineering Data
Volts 115 Volts 230 Volts
F.L. Amps 33.8 F.L. Amps 16.9 F.L. Amps
S. F Amps 37.8 S. F Amps 18.9 S. F Amps
RPM 1800 Hertz 60
HP 3 Duty CONTINUOUS TYPE CD
KW 2.24
Frame 184TC Serv. Factor 1.15 Phase 1
Max Amb 40 Design L Code J
Insul Class F Protection NOT Therm.Prot.
Eff 100% 75.5 Eff 75% PF 76
UL Yes CSA Yes Bearing OPE 6205
CC Number CE No Bearing PE 6206
Load Type Inverter Type Speed Range NONE
Motor Wt. 76 LB Enclosure DP Lubrication POLYREX EM
Nameplate 081285 Mounting ROUND Rotation SELECTIVE CCW
Assembly 180-014 Shaft Dia. 1 1/8 IN Ext. Diag. 005062.01
Cust Part No Outline 035371-1000 Ext. Diag2
Packaging B Winding C8428
Carton Label Leeson Gen Purpose GROUP: 3
Iris Paint STANDARD Test Card 01
Form Factor RMS Amps Const Torque Speed Range
Torque Peak
AB Code Peak@DegC
Resistance
Connection
Rework Status Rework TYPE
Hazardous Loc NONE Brake Motors
Explosion Proof Temp Op Code FORCE
Class GROUP: VDC
Class GROUP: ADC
Brake Coil OHMs @25 C
Performance
Torque UOM LB-FT Inertia (WK²) 1 LB-FT^2
Torque 9(Full Load) 18.4(Break Down) 17.5(Pull Up) 24.6(Locked Rotor)
CURRENT (amps) 16.6(Full Load) 0(Break Down) 0(Pull Up) 90.6(Locked Rotor)
Efficiency (%) 0(Full Load) 75.5(75% Load) 74.2(50% Load) 63.4(25% Load)
PowerFactor 0(Full Load) 73(75% Load) 71.3(50% Load) 43(25% Load)
Load Curve Data @60 Hz, 230 Volts, 3 Horsepower
Load Amps KW RPM Torque EFF PF Rise By Resis Frame Rise
0.0 9.7 0.355 1797 0.0 0.0 15.9 0.0 -
0.25 10.3 0.955 1787 2.25 63.4 43.0 0.0 -
0.5 11.7 1.556 1775 4.5 74.2 71.3 0.0 -
0.75 13.9 2.227 1763 6.75 75.5 73.0 0.0 -
1.0 16.9 2.975 1745 9.0 75.5 76.0 65.0 45.0
1.25 20.3 3.809 1727 11.25 72.5 81.5 0.0 -
1.5 24.9 4.795 1698 13.5 68.0 83.7 0.0 -
1.15 18.5 3.26 1735 10.3 78.9 81.8 95.0 60.0
SOURCE: CALCULATED GROUP: 3