Industrial Motors
Couldn't load pickup availability
131602.00, 5 HP, 1800 RPM, 184TC FR, TEFC, 230 Vac, 1 PH, C Face Less Base, High Torque.
Engineering Data
Volts 230 Volts Volts
F.L. Amps 20.5 F.L. Amps F.L. Amps
S. F Amps 23.6 S. F Amps S. F Amps
RPM 1800 Hertz 60
HP 5 Duty CONTINUOUS TYPE KF
KW 3.70
Frame 184TC Serv. Factor 1.15 Phase 1
Max Amb 40 Design L Code H
Insul Class F Protection MANUAL Therm.Prot. LED964
Eff 100% 82.5 Eff 75% PF 93
UL Yes CSA Yes Bearing OPE 6205
CC Number EXEMPT CE No Bearing PE 6206
Load Type Inverter Type Speed Range NONE
Motor Wt. 107 LB Enclosure TEFC Lubrication POLYREX EM
Nameplate 081285 Mounting ROUND Rotation SELECTIVE CCW
Assembly 180-034 Shaft Dia. 1 1/8 IN Ext. Diag. 005056.03
Cust Part No Outline 035379-1200 Ext. Diag2
Packaging B Winding K8483
Carton Label Leeson Farm Duty GROUP: 2
Iris Paint RED Test Card 01
Form Factor RMS Amps Const Torque Speed Range
Torque Peak
AB Code Peak@DegC
Resistance
Connection
Rework Status Rework TYPE
Hazardous Loc NONE Brake Motors
Explosion Proof Temp Op Code FORCE
Class GROUP: VDC
Class GROUP: ADC
Brake Coil OHMs @25 C
Performance
Torque UOM LB-FT Inertia (WK²) .61 LB-FT^2
Torque 15(Full Load) 35.5(Break Down) 26.5(Pull Up) 43.5(Locked Rotor)
CURRENT (amps) 20.5(Full Load) 0(Break Down) 0(Pull Up) 150(Locked Rotor)
Efficiency (%) 0(Full Load) 82.4(75% Load) 77.9(50% Load) 64.9(25% Load)
PowerFactor (Full Load) 94.4(75% Load) 92.1(50% Load) 83(25% Load)
Load Curve Data @60 Hz, 230 Volts, 5 Horsepower
Load Amps KW RPM Torque EFF PF Rise By Resis Frame Rise
0.0 5.5 0.6 1795 0.0 0.0 47.4 0.0 -
0.25 7.7 1.47 1790 3.75 64.9 83.0 0.0 -
0.5 11.5 2.437 1781 7.5 77.9 92.1 0.0 -
0.75 15.9 3.451 1771 11.3 82.4 94.4 0.0 -
1.0 20.5 4.51 1753 15.0 82.8 95.7 85.0 -
1.25 25.7 5.636 1747 18.8 82.8 95.3 0.0 -
1.5 31.4 6.891 1731 22.5 80.3 95.4 0.0 -
SOURCE: CALCULATED GROUP: 2