Industrial Motors
Couldn't load pickup availability
131848.00, 7.5-10 HP, 3600 RPM, 182TZ FR, DP Air Over, 230 Vac, 1 PH, Rigid Base, Crop Dryer
Engineering Data
Volts 230 Volts Volts
F.L. Amps 31-42 F.L. Amps F.L. Amps
S. F Amps S. F Amps S. F Amps
RPM 3600 Hertz 60
HP 7.5-10 Duty AIROVER TYPE KD
KW
Frame 182TZ Serv. Factor 1.0 Phase 1
Max Amb 40 Design L Code G
Insul Class F Protection AUTOMATIC Therm.Prot. 9700K66
Eff 100% 82.5 Eff 75% PF 93.5
UL Y-(LEESON UL REC) CSA Yes Bearing OPE 6205
CC Number EXEMPT CE No Bearing PE 6206
Load Type Inverter Type Speed Range NONE
Motor Wt. 98 LB Enclosure DP Lubrication POLYREX EM
Nameplate 081285 Mounting RIGID Rotation SELECTIVE CCW
Assembly 180-007 Shaft Dia. 1 1/8 IN Ext. Diag. 005018.30
Cust Part No Outline 035732-1150 Ext. Diag2
Packaging B Winding K8228
Carton Label Leeson Farm Duty GROUP: 2
Iris Paint 305025.01 Test Card 01
Form Factor RMS Amps Const Torque Speed Range
Torque Peak
AB Code Peak@DegC
Resistance
Connection
Rework Status Rework TYPE
Hazardous Loc NONE Brake Motors
Explosion Proof Temp Op Code FORCE
Class GROUP: VDC
Class GROUP: ADC
Brake Coil OHMs @25 C
Performance
Torque UOM LB-FT Inertia (WK²) .24 LB-FT^2
Torque 11.17(Full Load) 30(Break Down) 24.2(Pull Up) 26(Locked Rotor)
CURRENT (amps) 31(Full Load) 130(Break Down) 233(Pull Up) 235(Locked Rotor)
Efficiency (%) 0(Full Load) 82(75% Load) 78.3(50% Load) 67.5(25% Load)
PowerFactor 0(Full Load) 92.5(75% Load) 91.9(50% Load) 81.8(25% Load)
Load Curve Data @60 Hz, 230 Volts, 7.5-10 Horsepower
Load Amps KW RPM Torque EFF PF Rise By Resis Frame Rise
Load Curve Data Not Available