131881.00, 5 HP, 3600 RPM, 184JP FR, DP, 230 Vac, 1 PH, Rigid Base, JP Pump.
Engineering Data
Volts 208-230 Volts Volts
F.L. Amps 24-22 F.L. Amps F.L. Amps
S. F Amps 27-24.5 S. F Amps S. F Amps
RPM 3600 Hertz 60
HP 5 Duty CONTINUOUS TYPE KD
KW 3.73
Frame 184JP Serv. Factor 1.15 Phase 1
Max Amb 40 Design L Code G
Insul Class F Protection NOT Therm.Prot.
Eff 100% 80 Eff 75% PF 92
UL Yes CSA Yes Bearing OPE 6205
CC Number CE No Bearing PE 6207
Load Type Inverter Type Speed Range NONE
Motor Wt. 95 LB Enclosure DP Lubrication POLYREX EM
Nameplate 081285 Mounting RIGID Rotation SELECTIVE CCW
Assembly 180-024 Shaft Dia. 7/8 IN Ext. Diag. 005018.01
Cust Part No Outline 035751-1050 Ext. Diag2
Packaging B Winding K8222
Carton Label Leeson Pump GROUP: 2
Iris Paint STANDARD Test Card 01
Form Factor RMS Amps Const Torque Speed Range
Torque Peak
AB Code Peak@DegC
Resistance
Connection
Rework Status Rework TYPE
Hazardous Loc NONE Brake Motors
Explosion Proof Temp Op Code FORCE
Class GROUP: VDC
Class GROUP: ADC
Brake Coil OHMs @25 C
Performance
Torque UOM LB-FT Inertia (WK²) .16 LB-FT^2
Torque 7.5(Full Load) 19.2(Break Down) 16(Pull Up) 19(Locked Rotor)
CURRENT (amps) 22.2(Full Load) 0(Break Down) 0(Pull Up) 141(Locked Rotor)
Efficiency (%) 0(Full Load) 78.5(75% Load) 75.1(50% Load) 63.2(25% Load)
PowerFactor (Full Load) 91.3(75% Load) 86.3(50% Load) 73.7(25% Load)
Load Curve Data @60 Hz, 230 Volts, 5 Horsepower
Load Amps KW RPM Torque EFF PF Rise By Resis Frame Rise
0.0 6.9 0.492 3597 0.0 0.0 31.0 0.0 -
0.25 9.03 1.526 3574 1.9 63.2 73.7 0.0 -
0.5 12.69 2.52 3552 3.75 75.1 86.3 0.0 -
0.75 17.15 3.606 3529 5.65 78.5 91.3 0.0 -
1.0 22.2 4.68 3501 7.5 80.0 93.0 44.9 -
1.25 27.16 5.885 3470 9.4 78.8 94.1 0.0 -
1.5 33.3 7.205 3433 11.3 76.5 94.1 0.0 -
SOURCE: CALCULATED GROUP: 2