Industrial Motors
Couldn't load pickup availability
170116.60, 15 HP, 1800 RPM, 254T FR, TEFC, 575 Vac, 3 PH, Rigid Base, Special Voltage.
Engineering Data
Volts 575 Volts Volts
F.L. Amps 14.5 F.L. Amps F.L. Amps
S. F Amps 16.8 S. F Amps S. F Amps
RPM 1800 Hertz 60
HP 15 Duty CONTINUOUS TYPE TF
KW 11.2
Frame 254T Serv. Factor 1.15 Phase 3
Max Amb 40 Design B Code H
Insul Class F Protection NOT Therm.Prot.
Eff 100% 92.4 Eff 75% PF 84
UL Yes CSA Yes Bearing OPE 6308
CC Number CC005A CE Yes Bearing PE 6309
Load Type Inverter Type Speed Range NONE
Motor Wt. 290 LB Enclosure TEFC Lubrication STANDARD
Nameplate 081103 Mounting RIGID Rotation REV
Assembly Shaft Dia. 1-9/14 IN Ext. Diag. 005190.01
Cust Part No Outline 16953860 Ext. Diag2
Packaging 307997.99 Winding T12904005
Carton Label INDIVIDUAL GROUP: 4
Iris Paint VERIFY Test Card
Form Factor RMS Amps Const Torque Speed Range
Torque Peak
AB Code Peak@DegC
Resistance
Connection
Rework Status Rework TYPE
Hazardous Loc NONE Brake Motors
Explosion Proof Temp Op Code FORCE
Class GROUP: VDC
Class GROUP: ADC
Brake Coil OHMs @25 C
Performance
Torque UOM LB-FT Inertia (WK²) 2.09 LB-FT^2
Torque 44.7(Full Load) 134.1(Break Down) 97.4(Pull Up) 110.4(Locked Rotor)
CURRENT (amps) 14.5(Full Load) 0(Break Down) 0(Pull Up) 102(Locked Rotor)
Efficiency (%) 0(Full Load) 93(75% Load) 92.4(50% Load) 87.5(25% Load)
PowerFactor (Full Load) 77.5(75% Load) 67(50% Load) 44(25% Load)
Load Curve Data @60 Hz, 575 Volts, 15 Horsepower
Load Amps KW RPM Torque EFF PF Rise By Resis Frame Rise
0.0 6.3 0.34 1800 0.0 0.0 5.5 0.0 -
0.25 7.2 3.2 1795 11.0 87.5 44.0 0.0 -
0.5 9.1 6.1 1785 22.0 92.4 67.0 0.0 -
0.75 11.5 9.0 1780 33.3 93.0 77.5 0.0 -
1.0 14.5 12.0 1770 44.5 92.4 82.0 55.5 -
1.15 16.8 13.8 1768 51.4 92.4 84.0 0.0 -
1.25 18.0 15.1 1765 55.9 92.4 84.5 85.5 -
1.5 21.5 18.3 1755 67.3 91.7 85.5 0.0 -