170149.60, 60 HP, 1200 RPM, 404T FR, DP, 208-230/460 Vac, 3 PH, Rigid Base, General Purpose.
Engineering Data
Volts 208-230 Volts 460 Volts 190/380
F.L. Amps 169-160 F.L. Amps 80 F.L. Amps 160/80
S. F Amps 207-196 S. F Amps 98 S. F Amps 182/91
RPM 1200 Hertz 60/50
HP 60 Duty CONTINUOUS TYPE TD
KW 45
Frame 404T Serv. Factor 1.25 Phase 3
Max Amb 40 Design B Code F
Insul Class F Protection NOT Therm.Prot.
Eff 100% 94.5 Eff 75% PF 74.5
UL V-INS, CONST UL REC CSA No Bearing OPE 6314
CC Number CC005A CE Yes Bearing PE 6316
Load Type Inverter Type Speed Range NONE
Motor Wt. 1031 LB Enclosure DP Lubrication STANDARD
Nameplate 081023 Mounting RIGID Rotation REV
Assembly Shaft Dia. Ext. Diag. 004172.01
Cust Part No Outline 169558.60 Ext. Diag2
Packaging B Winding T19606019
Carton Label GROUP: 3
Iris Paint GREEN - LEESON WATTSAVER Test Card
Form Factor RMS Amps Const Torque Speed Range
Torque Peak
AB Code Peak@DegC
Resistance
Connection
Rework Status Rework TYPE
Hazardous Loc NONE Brake Motors
Explosion Proof Temp Op Code FORCE
Class GROUP: VDC
Class GROUP: ADC
Brake Coil OHMs @25 C
Performance
Torque UOM Inertia (WK²)
Torque
CURRENT (amps)
Efficiency (%)
PowerFactor
Load Curve Data @60/50 Hz, 460 Volts, 60 Horsepower
Load Amps KW RPM Torque EFF PF Rise By Resis Frame Rise
0.0 36.5 1.2 1200 0.0 0.0 4.0 0.0 -
0.25 42.0 12.5 1198 66.0 89.5 37.0 0.0 -
0.5 51.5 24.0 1195 132.0 93.0 58.0 0.0 -
0.75 65.0 35.5 1193 198.0 94.1 69.0 0.0 -
1.0 80.0 47.5 1190 265.0 94.5 74.5 45.0 -
1.15 90.5 54.5 1189 305.0 94.5 75.5 65.0 -
1.25 98.0 59.5 1187 332.0 94.1 76.0 80.0