Industrial Motors
Couldn't load pickup availability
170212.60, 10 HP, 1800 RPM, 215T FR, TEFC, 575 Vac, 3 PH, Rigid Base, Special Voltage.
Engineering Data
Volts 575 Volts Volts
F.L. Amps 10 F.L. Amps F.L. Amps
S. F Amps 11.2 S. F Amps S. F Amps
RPM 1800 Hertz 60
HP 10 Duty CONTINUOUS TYPE TF
KW 7.5
Frame 215T Serv. Factor 1.15 Phase 3
Max Amb 40 Design B Code H
Insul Class F Protection NOT Therm.Prot.
Eff 100% 91.7 Eff 75% PF 81.6
UL Yes CSA Yes Bearing OPE 6306
CC Number CC005A CE Yes Bearing PE 6308
Load Type Inverter Type Speed Range NONE
Motor Wt. 180 LB Enclosure TEFC Lubrication STANDARD
Nameplate 080443 Mounting RIGID Rotation REV
Assembly Shaft Dia. 1-5/14 IN Ext. Diag. 005102.01
Cust Part No Outline 16953660 Ext. Diag2
Packaging 307997.99 Winding T10704006
Carton Label INDIVIDUAL GROUP: 4
Iris Paint VERIFY Test Card
Form Factor RMS Amps Const Torque Speed Range
Torque Peak
AB Code Peak@DegC
Resistance
Connection
Rework Status Rework TYPE
Hazardous Loc NONE Brake Motors
Explosion Proof Temp Op Code FORCE
Class GROUP: VDC
Class GROUP: ADC
Brake Coil OHMs @25 C
Performance
Torque UOM LB-FT Inertia (WK²) 1.039 LB-FT^2
Torque 29.8(Full Load) 97.1(Break Down) 51.3(Pull Up) 65.6(Locked Rotor)
CURRENT (amps) 10(Full Load) 0(Break Down) 0(Pull Up) 70(Locked Rotor)
Efficiency (%) 0(Full Load) 92.2(75% Load) 91.3(50% Load) 86.8(25% Load)
PowerFactor (Full Load) 76.3(75% Load) 64.9(50% Load) 43(25% Load)
Load Curve Data @60 Hz, 575 Volts, 10 Horsepower
Load Amps KW RPM Torque EFF PF Rise By Resis Frame Rise
0.0 4.7 0.0 0 0.0 0.0 0.0 0.0 -
0.25 - 0.0 0 0.0 86.8 43.0 0.0 -
0.5 - 0.0 0 0.0 91.3 64.9 0.0 -
0.75 - 0.0 0 0.0 92.2 76.3 0.0 -
1.0 - 0.0 0 0.0 91.7 81.6 50.0 -
1.25 - 0.0 0 0.0 0.0 0.0 0.0 -
1.5 - 0.0 0 0.0 0.0 0.0 0.0