171449.60, 150 HP, 3600 RPM, 405TS FR, DP, 460 Vac, 3 PH, Rigid Base, General Purpose.
Engineering Data
Volts 460 Volts Volts 380
F.L. Amps 169 F.L. Amps F.L. Amps 171
S. F Amps 197 S. F Amps S. F Amps 201
RPM 3600 Hertz 60/50
HP 150 Duty CONTINUOUS TYPE TD
KW 112
Frame 405TS Serv. Factor 1.15 Phase 3
Max Amb 40 Design B Code F
Insul Class F Protection NOT Therm.Prot.
Eff 100% 94.5 Eff 75% PF 87.5
UL Y-(LEESON UL REC) CSA Yes Bearing OPE 6314
CC Number CC005A CE Yes Bearing PE 6316
Load Type Inverter Type Speed Range NONE
Motor Wt. 1173 LB Enclosure DP Lubrication POLYREX EM
Nameplate 081103 Mounting RIGID Rotation REV
Assembly Shaft Dia. 2 1/8 IN Ext. Diag. 005190.01
Cust Part No Outline 16955960 Ext. Diag2
Packaging B Winding T19602011
Carton Label INDIVIDUAL GROUP: 3
Iris Paint VERIFY Test Card 00
Form Factor RMS Amps Const Torque Speed Range
Torque Peak
AB Code Peak@DegC
Resistance
Connection
Rework Status Rework TYPE
Hazardous Loc NONE Brake Motors
Explosion Proof Temp Op Code FORCE
Class GROUP: VDC
Class GROUP: ADC
Brake Coil OHMs @25 C
Performance
Torque UOM LB-FT Inertia (WK²)
Torque 221.5(Full Load) 519(Break Down) 267(Pull Up) 320(Locked Rotor)
CURRENT (amps) 170(Full Load) 550(Break Down) 900(Pull Up) 935(Locked Rotor)
Efficiency (%) 0(Full Load) 95(75% Load) 95(50% Load) 93.6(25% Load)
PowerFactor (Full Load) 87(75% Load) 82.5(50% Load) 67(25% Load)
Load Curve Data @60/50 Hz, 460 Volts, 150 Horsepower
Load Amps KW RPM Torque EFF PF Rise By Resis Frame Rise
0.0 39.0 1.8 3600 0.0 0.0 6.0 0.0 -
0.25 56.0 60.455 3590 54.9 93.6 67.0 0.0 -
0.5 89.0 58.6 3580 110.0 95.0 82.5 0.0 -
0.75 128.0 88.0 3570 165.5 95.0 87.0 0.0 -
1.0 170.0 118.1 3555 221.5 94.5 87.0 62.0 -
1.25 217.5 149.0 3540 278.0 93.6 86.0 107.0 -
1.5 270.0 181.0 3525 335.0 92.4 84.0 0.0