Industrial Motors
Couldn't load pickup availability
171631.60, 10 HP, 1800 RPM, 215T FR, TEFC, 208-230/460 Vac, 3 PH, Rigid Base, Wattsaver Plus.
Engineering Data
Volts 208-230 Volts 460 Volts 190/380
F.L. Amps 27-25 F.L. Amps 12.5 F.L. Amps 23/11.5
S. F Amps 28 S. F Amps 14 S. F Amps 25.8/12.9
RPM 1800 Hertz 60/50
HP 10 Duty CONTINUOUS TYPE TF
KW 7.5
Frame 215T Serv. Factor 1.25 Phase 3
Max Amb 40 Design B Code H
Insul Class F Protection NOT Therm.Prot.
Eff 100% 91.7 Eff 75% PF 81.6
UL V-INS, CONST UL REC CSA No Bearing OPE NONE
CC Number CC005A CE Yes Bearing PE NONE
Load Type Inverter Type Speed Range NONE
Motor Wt. 187 LB Enclosure TEFC Lubrication STANDARD
Nameplate Mounting RIGID Rotation REV
Assembly Shaft Dia. Ext. Diag. 005010.20
Cust Part No Outline SS622138LE Ext. Diag2
Packaging P Winding T10704006
Carton Label GROUP: 3
Iris Paint STANDARD Test Card
Form Factor RMS Amps Const Torque Speed Range
Torque Peak
AB Code Peak@DegC
Resistance
Connection
Rework Status Rework TYPE
Hazardous Loc NONE Brake Motors
Explosion Proof Temp Op Code FORCE
Class GROUP: VDC
Class GROUP: ADC
Brake Coil OHMs @25 C
Performance
Torque UOM LB-FT Inertia (WK²) 1.039 LB-FT^2
Torque 29.8(Full Load) 97.1(Break Down) 51.3(Pull Up) 65.6(Locked Rotor)
CURRENT (amps) 25(Full Load) 0(Break Down) 0(Pull Up) 175(Locked Rotor)
Efficiency (%) 0(Full Load) 92.2(75% Load) 91.3(50% Load) 86.8(25% Load)
PowerFactor (Full Load) 76.3(75% Load) 64.9(50% Load) 43(25% Load)
Load Curve Data @60/50 Hz, 460 Volts, 10 Horsepower
Load Amps KW RPM Torque EFF PF Rise By Resis Frame Rise
0.0 11.8 0.0 0 0.0 0.0 0.0 0.0 -
0.25 - 0.0 0 0.0 86.8 43.0 0.0 -
0.5 - 0.0 0 0.0 91.3 64.9 0.0 -
0.75 - 0.0 0 0.0 92.2 76.3 0.0 -
1.0 - 0.0 0 0.0 91.7 81.6 50.0 -
1.25 - 0.0 0 0.0 0.0 0.0 0.0 -
1.5 - 0.0 0 0.0 0.0 0.0 0.0