Industrial Motors
Couldn't load pickup availability
191870.00, 1/2 HP, 1800 RPM, 48 FR, DP, 115/230 Vac, 1 PH, Resilient Base, Fan & Blower
Engineering Data
Volts 115 Volts 230 Volts
F.L. Amps 8.4 F.L. Amps 4.2 F.L. Amps
S. F Amps 9.2 S. F Amps 4.6 S. F Amps
RPM 1800 Hertz 60
HP 1/2 Duty CONTINUOUS TYPE SD
KW 0.37
Frame 48 Serv. Factor 1.25 Phase 1
Max Amb 40 Design N Code M
Insul Class B Protection AUTOMATIC Therm.Prot. CEG65GV
Eff 100% 66 Eff 75% PF 59
UL Yes CSA Yes Bearing OPE 203
CC Number - CE No Bearing PE 203
Load Type Inverter Type Speed Range NONE
Motor Wt. 22 LB Enclosure DP Lubrication STANDARD
Nameplate Mounting RESILIENT BASE Rotation SELECTIVE CCW
Assembly Shaft Dia. 1/2 IN Ext. Diag. 00521210
Cust Part No Outline 169872-550 Ext. Diag2
Packaging 307997.99 Winding QS5541
Carton Label INDIVIDUAL GROUP: 3
Iris Paint NAN Test Card
Form Factor RMS Amps Const Torque Speed Range
Torque Peak
AB Code Peak@DegC
Resistance
Connection
Rework Status Rework TYPE
Hazardous Loc NONE Brake Motors
Explosion Proof Temp Op Code FORCE
Class GROUP: VDC
Class GROUP: ADC
Brake Coil OHMs @25 C
Performance
Torque UOM OZ-FT Inertia (WK²) -1 LB-FT^2
Torque 24(Full Load) 55.7(Break Down) 29.8(Pull Up) 31.8(Locked Rotor)
CURRENT (amps) 4.2(Full Load) 0(Break Down) 0(Pull Up) 19(Locked Rotor)
Efficiency (%) 0(Full Load) 64.1(75% Load) 56.4(50% Load) 41.3(25% Load)
PowerFactor (Full Load) 49.9(75% Load) 40.3(50% Load) 29.1(25% Load)
Load Curve Data @60 Hz, 230 Volts, 1/2 Horsepower
Load Amps KW RPM Torque EFF PF Rise By Resis Frame Rise
0.0 3.53 0.0 0 0.0 0.0 0.0 0.0 -
0.25 3.51 0.235 1783 6.13 41.3 29.1 0.0 -
0.5 3.6 0.334 1769 12.0 56.4 40.3 0.0 -
0.75 3.83 0.44 1753 18.13 64.1 49.9 0.0 -
1.0 4.13 0.554 1736 24.0 66.8 58.3 0.0 -
1.25 4.59 0.698 1714 30.13 65.7 66.1 0.0 -
1.5 5.12 0.839 1691 35.73 63.9 71.2 0.0 -
1.75 5.69 0.976 1663 41.87 63.3 74.6 0.0 -
2.0 6.58 1.141 1623 48.0 60.6 75.4 0.0 -
SOURCE: CALCULATED GROUP: 3