Industrial Motors
Couldn't load pickup availability
194184.00, 60 Hp, 1200 Rpm, 404T FR, 230/460 Vac, 3 PH, TEFC, Rigid Base, Aggregate/Crusher Duty, Definite Purpose Motor.
Engineering Data
Volts 230 Volts 460 Volts 190/380
F.L. Amps 144 F.L. Amps 72 F.L. Amps 145/72.5
S. F Amps 164 S. F Amps 82 S. F Amps 167/83.5
RPM 1200 Hertz 60/50
HP 60 Duty CONTINUOUS TYPE TW
KW 45
Frame 404T Serv. Factor 1.15 Phase 3
Max Amb 40 Design C Code G
Insul Class F Protection NOT Therm.Prot.
Eff 100% 94.1 Eff 75% PF 83
UL Y-(LEESON UL REC) CSA Yes Bearing OPE 6315
CC Number CC005A CE No Bearing PE NU316
Load Type Inverter Type Speed Range NONE
Motor Wt. 1341 LB Enclosure TEFC Lubrication VERIFY
Nameplate B-93405-L-N-ABDFH-A-X Mounting RIGID Rotation REV
Assembly Shaft Dia. Ext. Diag. A-EE7300CB-LE
Cust Part No Outline SS620676 Ext. Diag2
Packaging N Outline Dash No Winding CHT40460003
Carton Label GROUP : 1
Iris Paint BLUE (EPOXY) Test Card
Form Factor RMS Amps Const Torque Speed Range
Torque Peak
AB Code Peak@DegC
Resistance
Connection
Rework Status Rework TYPE
Hazardous Loc NONE Brake Motors
Explosion Proof Temp Op Code FORCE
Class GROUP : VDC
Class GROUP : ADC
Brake Coil OHMs @25 C
Performance
Torque UOM Inertia (WK²)
Torque
CURRENT (amps)
Efficiency (%)
PowerFactor
Load Curve Data @60/50 Hz , 380 Volts , 60 Horsepower
Load Amps KW2 RPM Torque EFF PF Rise By Resis Frame Rise
0.0 26.0 1.5 1200 0.0 0.0 5.5 0.0 -
0.25 31.0 12.2 1198 66.0 89.5 51.0 0.0 -
0.5 42.0 23.8 1195 132.0 93.0 71.0 0.0 -
0.75 56.0 35.5 1192 199.0 94.1 80.0 0.0 -
1.0 72.0 47.5 1188 265.0 94.1 83.0 75.0 -
1.15 82.0 54.5 1186 306.0 93.6 84.0 105.0 -
1.25 89.0 60.0 1182 333.0 93.0 84.0 0.0 -