199008.00, 5HP..1200RPM.215T.TEFC.230/460V.3PH.60HZ.CONT.40C.1.15SF.RIGID......GENERAL PURPOSE.
Engineering Data
Volts 208-230 Volts 460 Volts 190/380
F.L. Amps 15-14 F.L. Amps 7 F.L. Amps 10/5
S. F Amps 16.5-15.4 S. F Amps 7.7 S. F Amps 11.4/5.7
RPM 1200 Hertz 60/50
HP 5 Duty CONTINUOUS TYPE TF
KW 3.7
Frame 215T Serv. Factor 1.15 Phase 3
Max Amb 40 Design B Code G
Insul Class F Protection NOT Therm.Prot.
Eff 100% 89.5 Eff 75% PF 75
UL Y-(LEESON UL REC) CSA Yes Bearing OPE 6206
CC Number CC005A CE No Bearing PE 6307
Load Type Inverter Type Speed Range NONE
Motor Wt. 185 LB Enclosure TEFC Lubrication STANDARD
Nameplate 93405-L-N-ABDFH-B-A Mounting RIGID Rotation REV
Assembly Shaft Dia. Ext. Diag. EE7308-LE
Cust Part No Outline SS620291 Ext. Diag2
Packaging F Winding CHT21560005
Carton Label GROUP: 1
Iris Paint GRAY (ENAMEL) Test Card
Form Factor RMS Amps Const Torque Speed Range
Torque Peak
AB Code Peak@DegC
Resistance
Connection
Rework Status Rework TYPE
Hazardous Loc NONE Brake Motors
Explosion Proof Temp Op Code FORCE
Class GROUP: VDC
Class GROUP: ADC
Brake Coil OHMs @25 C
Performance
Torque UOM Inertia (WK²)
Torque
CURRENT (amps)
Efficiency (%)
PowerFactor
Load Curve Data @60/50 Hz, 460 Volts, 5 Horsepower
Load Amps KW RPM Torque EFF PF Rise By Resis Frame Rise
0.0 3.5 0.35 1200 0.0 0.0 5.0 0.0 -
0.25 3.8 1.2 1195 5.5 84.0 38.0 0.0 -
0.5 4.6 2.2 1190 11.0 88.5 59.0 0.0 -
0.75 5.7 3.2 1185 16.6 89.5 70.0 0.0 -
1.0 7.0 4.2 1182 22.2 89.5 75.0 45.0 -
1.15 7.7 4.8 1175 25.7 89.5 76.0 60.0 -
1.25 8.5 5.3 1170 28.0 88.5 77.0 75.0 -
SOURCE: CALCULATED GROUP: 1