199020.00 20HP..1200RPM.286T.TEFC.230/460V.3PH.60HZ.CONT.40C.1.15SF.RIGID......GENERAL PURPOSE
Engineering Data
Volts 230 Volts 460 Volts 190/380
F.L. Amps 52 F.L. Amps 26 F.L. Amps 49/24.5
S. F Amps 59 S. F Amps 29.5 S. F Amps 55/27.5
RPM 1200 Hertz 60/50
HP 20 Duty CONTINUOUS TYPE TF
KW 14.9
Frame 286T Serv. Factor 1.15 Phase 3
Max Amb 40 Design B Code F
Insul Class F Protection NOT Therm.Prot.
Eff 100% 91.7 Eff 75% PF 77
UL Y-(LEESON UL REC) CSA Yes Bearing OPE 6210
CC Number CC005A CE No Bearing PE 6311
Load Type Inverter Type Speed Range NONE
Motor Wt. 500 LB Enclosure TEFC Lubrication STANDARD
Nameplate 93405-L-N-ABDFH-A-B Mounting RIGID Rotation REV
Assembly Shaft Dia. Ext. Diag. EE7308AA-LE
Cust Part No Outline SS620245 Ext. Diag2
Packaging F Winding CHT28660001
Carton Label GROUP: 1
Iris Paint GRAY (ENAMEL) Test Card
Form Factor RMS Amps Const Torque Speed Range
Torque Peak
AB Code Peak@DegC
Resistance
Connection
Rework Status Rework TYPE
Hazardous Loc NONE Brake Motors
Explosion Proof Temp Op Code FORCE
Class GROUP: VDC
Class GROUP: ADC
Brake Coil OHMs @25 C
Performance
Torque UOM Inertia (WK²)
Torque
CURRENT (amps)
Efficiency (%)
PowerFactor
Load Curve Data @60/50 Hz, 460 Volts, 20 Horsepower
Load Amps KW RPM Torque EFF PF Rise By Resis Frame Rise
0.0 12.6 0.6 1200 0.0 0.0 4.5 0.0 -
0.25 13.9 4.3 1195 22.0 84.0 38.0 0.0 -
0.5 16.9 8.2 1190 44.0 90.2 60.0 0.0 -
0.75 21.0 12.2 1182 66.5 91.7 71.0 0.0 -
1.0 26.0 16.3 1175 89.0 91.7 77.0 65.0 -
1.15 29.5 18.8 1172 102.0 91.0 78.5 85.0 -
1.25 32.0 20.5 1170 112.0 90.2 79.0 105.0 -
SOURCE: CALCULATED GROUP: 1