(199043.00) 125HP..1800RPM.444T.TEFC.460V.3PH.60HZ.CONT.40C.1.15SF.RIGID......GENERAL PURPOSE
Engineering Data
Volts 460 Volts Volts 380
F.L. Amps 140 F.L. Amps F.L. Amps 135
S. F Amps 160 S. F Amps S. F Amps 156
RPM 1800 Hertz 60/50
HP 125 Duty CONTINUOUS TYPE TF
KW 93
Frame 444T Serv. Factor 1.15 Phase 3
Max Amb 40 Design B Code F
Insul Class F Protection NOT Therm.Prot.
Eff 100% 95.4 Eff 75% PF 88
UL Y-(LEESON UL REC) CSA Yes Bearing OPE 6317
CC Number CC005A CE No Bearing PE 6319
Load Type Inverter Type Speed Range NONE
Motor Wt. 1885 LB Enclosure TEFC Lubrication STANDARD
Nameplate 93405-L-N-ABDEF-D-A Mounting RIGID Rotation REV
Assembly Shaft Dia. Ext. Diag. A-EE7341C-LE
Cust Part No Outline B-SS620287 Ext. Diag2
Packaging F Winding CHT44440001
Carton Label GROUP: 1
Iris Paint GRAY (ENAMEL) Test Card
Form Factor RMS Amps Const Torque Speed Range
Torque Peak
AB Code Peak@DegC
Resistance
Connection
Rework Status Rework TYPE
Hazardous Loc NONE Brake Motors
Explosion Proof Temp Op Code FORCE
Class GROUP: VDC
Class GROUP: ADC
Brake Coil OHMs @25 C
Performance
Torque UOM Inertia (WK²)
Torque
CURRENT (amps)
Efficiency (%)
PowerFactor
Load Curve Data @60/50 Hz, 460 Volts, 125 Horsepower
Load Amps KW RPM Torque EFF PF Rise By Resis Frame Rise
0.0 36.0 2.5 1800 0.0 0.0 6.0 0.0 -
0.25 49.0 25.5 1796 91.5 93.0 65.0 0.0 -
0.5 76.0 49.2 1794 183.0 95.0 82.0 0.0 -
0.75 106.0 73.5 1790 275.0 95.4 87.0 0.0 -
1.0 140.0 97.5 1786 367.0 95.4 88.0 55.0 -
1.15 160.0 113.0 1784 423.0 95.0 88.0 75.0 -
1.25 175.0 123.0 1782 460.0 94.5 88.0 90.0 -
SOURCE: CALCULATED GROUP: 1