Industrial Motors
Couldn't load pickup availability
199971.00, 40 Hp, 3600 Rpm, 286JM FR, DP, 208-230/460 Vac, 3 PH, C-Face W/Base, JM Pump Motor.
Engineering Data
Volts 230 Volts 460 Volts 190/380
F.L. Amps 89 F.L. Amps 44.5 F.L. Amps 81/40.5
S. F Amps 103 S. F Amps 51.5 S. F Amps
RPM 3600 Hertz 60/50
HP 40 Duty CONTINUOUS TYPE TD
KW 30
Frame 286JM Serv. Factor 1.15 Phase 3
Max Amb 40 Design B Code F
Insul Class F Protection NOT Therm.Prot.
Eff 100% 92.4 Eff 75% PF 90
UL V-INS, CONST UL REC CSA No Bearing OPE 6211
CC Number CC005A CE Yes Bearing PE 6211
Load Type Inverter Type Speed Range NONE
Motor Wt. 529 LB Enclosure DP Lubrication POLYREX EM
Nameplate 93405 Mounting RIGID Rotation REV
Assembly Shaft Dia. Ext. Diag. A-EE7308AA
Cust Part No Outline B-SS620314 Ext. Diag2
Packaging N Outline Dash No Winding CHT28620002
Carton Label GROUP : 1
Iris Paint BLUE (ENAMEL) Test Card
Form Factor RMS Amps Const Torque Speed Range
Torque Peak
AB Code Peak@DegC
Resistance
Connection
Rework Status Rework TYPE
Hazardous Loc NONE Brake Motors
Explosion Proof Temp Op Code FORCE
Class GROUP : VDC
Class GROUP : ADC
Brake Coil OHMs @25 C
Performance
Torque UOM Inertia (WK²)
Torque
CURRENT (amps)
Efficiency (%)
PowerFactor
Load Curve Data @60/50 Hz , 380 Volts , 40 Horsepower
Load Amps KW2 RPM Torque EFF PF Rise By Resis Frame Rise
0.0 12.0 1.0 3600 0.0 0.0 7.0 0.0 -
0.25 16.0 8.5 3590 14.6 91.0 64.0 0.0 -
0.5 24.5 16.2 3580 29.5 91.7 82.0 0.0 -
0.75 34.0 24.0 3568 44.2 93.0 87.5 0.0 -
1.0 44.5 32.5 3555 59.0 92.4 90.0 35.0 -
1.15 51.5 37.0 3550 68.2 92.4 90.0 50.0 -
1.25 56.0 40.5 3545 74.2 92.4 90.0 60.0 -