Industrial Motors
Couldn't load pickup availability
131509.00, 2 HP, 1800 RPM, 182T FR, TEFC, 115/208-230 VAC, 1 PH, Rigid Base, General Purpose
Engineering Data
Volts 115 Volts 208-230 Volts
F.L. Amps 24.8 F.L. Amps 13-12.4 F.L. Amps
S. F Amps None S. F Amps S. F Amps
RPM 1800 Hertz 60
HP 2 Duty CONTINUOUS TYPE CF
KW 1.49
Frame 182T Serv. Factor 1.0 Phase 1
Max Amb 40 Design L Code K
Insul Class F Protection NOT Therm.Prot.
Eff 100% 72 Eff 75% PF 75
UL Yes CSA Yes Bearing OPE 6205
CC Number CE No Bearing PE 6206
Load Type Inverter Type Speed Range NONE
Motor Wt. 68 LB Enclosure TEFC Lubrication POLYREX EM
Nameplate 081285 Mounting RIGID Rotation SELECTIVE CCW
Assembly 180-033 Shaft Dia. 1 1/8 IN Ext. Diag. 005062.01
Cust Part No Outline 035347-900 Ext. Diag2
Packaging B Winding C842
Carton Label Leeson Gen Purpose GROUP: 3
Iris Paint STANDARD Test Card 02
Form Factor RMS Amps Const Torque Speed Range
Torque Peak
AB Code Peak@DegC
Resistance
Connection
Rework Status Rework TYPE
Hazardous Loc NONE Brake Motors
Explosion Proof Temp Op Code FORCE
Class GROUP: VDC
Class GROUP: ADC
Brake Coil OHMs @25 C
Performance
Torque UOM LB-FT Inertia (WK²) .306 LB-FT^2
Torque 6(Full Load) 16.1(Break Down) 15(Pull Up) 20.6(Locked Rotor)
CURRENT (amps) 12.4(Full Load) 0(Break Down) 0(Pull Up) 78(Locked Rotor)
Efficiency (%) 0(Full Load) 69.3(75% Load) 64.2(50% Load) 49.5(25% Load)
PowerFactor (Full Load) 62.5(75% Load) 50.7(50% Load) 36(25% Load)
Load Curve Data @60 Hz, 230 Volts, 2 Horsepower
Load Amps KW RPM Torque EFF PF Rise By Resis Frame Rise
0.0 9.0 0.373 1796 0.0 0.0 18.0 0.0 -
0.25 9.31 0.77 1788 1.5 49.5 36.0 0.0 -
0.5 10.13 1.182 1780 3.0 64.2 50.7 0.0 -
0.75 11.35 1.632 1770 4.5 69.3 62.5 0.0 -
1.0 12.11 2.074 1759 6.0 72.3 74.5 75.0 -
1.25 14.84 2.565 1747 7.5 72.6 75.1 0.0 -
1.5 17.02 3.088 1732 9.0 71.7 78.9 0.0 -
SOURCE: CALCULATED GROUP: 3