(110352.00) 2HP.3450RPM.56H.TEFC.115/208-230V.1PH.60HZ.CONT.NOT.40C.1.0SF.RIGID.GENERAL PURPOSE.C6C34FB21H
Volts 115 Volts 208-230 Volts
F.L. Amps 20 F.L. Amps 11.4-10 F.L. Amps
S. F Amps S. F Amps S. F Amps
RPM 3600 Hertz 60
HP 2 Duty CONTINUOUS TYPE CF
KW 1.49
Frame 56H Serv. Factor 1.0 Phase 1
Max Amb 40 Design L Code J
Insul Class F Protection NOT Therm.Prot.
Eff 100% 73 Eff 75% PF 87
UL Y-(LEESON UL REC) CSA Yes Bearing OPE 6203
CC Number EXEMPT CE No Bearing PE 6203
Load Type Inverter Type Speed Range NONE
Motor Wt. 44 LB Enclosure TEFC Lubrication POLYREX EM
Nameplate 993500 Mounting RIGID Rotation SELECTIVE CCW
Assembly NONE Shaft Dia. 5/8 IN Ext. Diag. 005062.01
Cust Part No Outline 028856-800 Ext. Diag2
Packaging B Winding C632213
Carton Label INDIVIDUAL GROUP: 3
Iris Paint 305000.01 Test Card 01
Form Factor RMS Amps Const Torque Speed Range
Torque Peak
AB Code Peak@DegC
Resistance
Connection
Rework Status Rework TYPE
Hazardous Loc NONE Brake Motors
Explosion Proof Temp Op Code FORCE
Class GROUP: VDC
Class GROUP: ADC
Brake Coil OHMs @25 C
Performance
Torque UOM LB-FT Inertia (WK²) .09 LB-FT^2
Torque 7.8(Break Down) 7(Pull Up) 7.5(Locked Rotor)
CURRENT (amps) 0(Break Down) 0(Pull Up) 64.4(Locked Rotor)
Efficiency (%) 72.9(75% Load) 71(50% Load) 59.9(25% Load)
PowerFactor 81.7(75% Load) 71.8(50% Load) 53.2(25% Load)
Load Curve Data @60 Hz, 230 Volts, 2 Horsepower
Load Amps KW RPM Torque EFF PF Rise By Resis Frame Rise
0.0 4.5 0.27 3598 0.0 0.0 26.1 0.0 -
0.25 5.2 0.636 3577 0.75 59.9 53.2 0.0 -
0.5 6.47 1.068 3556 1.5 71.0 71.8 0.0 -
0.75 8.25 1.55 3532 2.25 72.9 81.7 0.0 -
1.0 10.22 2.045 3503 3.0 73.0 87.0 90.0 -
1.25 12.96 2.368 3467 3.75 78.0 79.4 0.0 -
1.5 16.06 3.315 3415 4.5 65.9 89.7 0.0 -
SOURCE: CALCULATED GROUP: 3