Engineering Data
Output 50.000 hp @ 50 Hz
60.000 hp @ 60 Hz
Phase 3
Synchronous Speed 1,200 rpm
Frequency 50.00 Hz
60.00 Hz
Voltage 190 V @ 50 Hz
380 V @ 50 Hz
230 V @ 60 Hz
460 V @ 60 Hz
Frame Material Iron
Frame 404T
XP Class and Group Class I, Group C & D
XP Division Division I
Brand Baldor-Reliance
Agency Approvals CCSA US
CSA
CSA EEV
UL
Ambient Temperature 40 °C
Auxillary Box No Auxillary Box
Base Indicator Rigid
Bearing Grease Type POLYREX EM (-20F +300F)
Current 136.0 A @ 190 V
135.0 A @ 230 V
68.2 A @ 380 V
67.3 A @ 460 V
Design Code B
Drip Cover No Drip Cover
Duty Rating CONT
Efficiency @ 100% Load 94.5%
Feedback Device No feedback
Frame Prefix X
Heater Indicator No heater
High Voltage Full Load Amps 67.3 A
Insulation Class F
Inverter Code Inverter ready
KVA Code G
Lifting Lugs Standard Lifting Lugs
Motor Lead Quantity/Wire Size 3 @ 4 AWG
Motor Standards NEMA
Motor Type A40072M
Number of Poles 6
Overall Length 38.21 in
Power Factor 88
Product Family General Industrial
Pulley End Bearing Type Ball
Pulley Face Code Standard
Service Factor 1.15
Shaft Diameter 2.875 in
Shaft Ground Indicator No Shaft Grounding
Shaft Rotation Reversible
Shaft Slinger Indicator Shaft Slinger
Speed 985 rpm
1,185 rpm
Speed Code Single Speed
Starting Method Direct on line
Thermal Device - Bearing NONE (OLD)
Thermal Device - Winding Normally Closed Thermostat
XP Temp Code T3C