Industrial Motors
Couldn't load pickup availability
**This Motor has been replaced by Model # 1199780.00**
G140622.00, 7 1/2 HP, 1800 RPM, 215JM FR, DP, 208-203/460 Vac, 1 PH, Rigid Base, JM Pump
Engineering Data
Volts 208-230 Volts 460 Volts 190/380
F.L. Amps 24-22 F.L. Amps 11 F.L. Amps 18/9
S. F Amps 26-24 S. F Amps 12 S. F Amps 20/10
RPM 1800 Hertz 60/50
HP 7 1/2 Duty CONTINUOUS TYPE TF
KW 5.60
Frame 213JM Serv. Factor 1.15 Phase 3
Max Amb 40 Design B Code H
Insul Class F Protection NOT Therm.Prot.
Eff 100% 89.5 Eff 75% PF 72
UL Y-(LEESON UL REC) CSA Yes Bearing OPE 6206
CC Number EXEMPT CE Yes Bearing PE 6209
Load Type Inverter Type Speed Range NONE
Motor Wt. 127 LB Enclosure TEFC Lubrication POLYREX EM
Nameplate 081284 Mounting RIGID Rotation REV
Assembly 210-003.01 Shaft Dia. 7/8 IN Ext. Diag. 005010.01
Cust Part No Outline 037619-1100 Ext. Diag2
Packaging B Outline Dash No Winding T9490
Carton Label Leeson Pump GROUP : 3
Iris Paint STANDARD Test Card 01
Form Factor RMS Amps Const Torque Speed Range
Torque Peak
AB Code Peak@DegC
Resistance
Connection
Rework Status Rework TYPE
Hazardous Loc NONE Brake Motors
Explosion Proof Temp Op Code FORCE
Class GROUP : VDC
Class GROUP : ADC
Brake Coil OHMs @25 C
Performance
Torque UOM LB-FT Inertia (WK²) .801 LB-FT^2
Torque 22.5(Full Load) 72(Break Down) 47(Pull Up) 51.5(Locked Rotor)
CURRENT (amps) 10.2(Full Load) 0(Break Down) 0(Pull Up) 70(Locked Rotor)
Efficiency (%) 0(Full Load) 87.7(75% Load) 86.4(50% Load) 77.6(25% Load)
PowerFactor (Full Load) 74.4(75% Load) 65(50% Load) 46.1(25% Load)
Load Curve Data @60/50 Hz , 380 Volts , 7 1/2 Horsepower
Load Amps KW2 RPM Torque EFF PF Rise By Resis Frame Rise
0.0 4.4 0.3 1798 0.0 0.0 8.5 0.0 -
0.25 5.0 1.837 1791 5.6 77.6 46.1 0.0 -
0.5 6.4 3.313 1783 11.3 86.4 65.0 0.0 -
0.75 8.2 4.86 1774 16.9 87.7 74.4 0.0 -
1.0 10.2 6.417 1765 22.5 87.9 79.0 56.5 -
1.25 12.4 8.013 1754 28.1 87.4 81.1 0.0 -
1.5 14.8 9.613 1743 33.8 87.1 81.5 0.0 -