141275.00, 10 HP, 3600 RPM, 215JM FR, TEFC, 208-230/460 Vac, 3 PH, C-Face with Base, Stainless Steel JM Pump Motor

Engineering Data

Volts 208-230 Volts 460 Volts 190/380
F.L. Amps 27-24 F.L. Amps 12 F.L. Amps 22/11
S. F Amps 30.5-27 S. F Amps 13.5 S. F Amps 24.8/12.4

--------------------------------------------------------------------------------

RPM 3600 Hertz 60/50
HP 10 Duty CONTINUOUS TYPE TF
KW 7.50
Frame 215JM Serv. Factor 1.15 Phase 3
Max Amb 40 Design B Code G
Insul Class F Protection NOT Therm.Prot.
Eff 100% 89.5 Eff 75% PF 87
UL Y-(LEESON UL REC) CSA Yes Bearing OPE 6207
CC Number EXEMPT CE Yes Bearing PE 6209
Load Type Inverter Type Speed Range NONE

--------------------------------------------------------------------------------

Motor Wt. 169 LB Enclosure TEFC Lubrication POLYREX EM
Nameplate 081119 Mounting RIGID Rotation REV
Assembly 210-023.01 Shaft Dia. 7/8 IN Ext. Diag. 005010.01
Cust Part No Outline 037618 Ext. Diag2
Packaging B Outline Dash No Winding K2152190
Carton Label Leeson Stainless Washguard GROUP: 1
Iris Paint NONE Test Card

--------------------------------------------------------------------------------

Form Factor RMS Amps Const Torque Speed Range
Torque Peak
AB Code Peak@DegC
Resistance
Connection

--------------------------------------------------------------------------------

Rework Status Rework TYPE

--------------------------------------------------------------------------------

Hazardous Loc NONE Brake Motors
Explosion Proof Temp Op Code FORCE
Class GROUP: VDC
Class GROUP: ADC
Brake Coil OHMs @25 C
Performance
Torque UOM Inertia (WK²)
Torque
CURRENT (amps)
Efficiency (%)
PowerFactor
Load Curve Data @60/50 Hz, 460 Volts, 10 Horsepower
Load Amps KW RPM Torque Eff PF Rise By Resis Frame Rise
0.0 4.9 0.6 3600 0.0 0.0 10.0 0.0 -
0.25 5.8 2.3 3580 3.7 81.5 49.0 0.0 -
0.5 7.6 4.3 3565 7.5 87.5 70.5 0.0 -
0.75 10.0 6.3 3545 11.0 89.5 80.0 0.0 -
1.0 12.0 8.3 3525 15.0 89.5 87.0 50.0 -
1.15 13.5 9.6 3515 17.0 89.5 87.5 70.0 -
1.25 15.0 10.5 3505 19.0 88.5 88.0 100.0 -
SOURCE CALCULATED GROUP