Industrial Motors
Couldn't load pickup availability
119472.00, 2 Hp, 3600 Rpm, 56C FR, 208-230/460 Vac, 3 PH, TENV, C-Face Less Base, Washguard Motor
Engineering Data
Volts 208-230 Volts 460 Volts
F.L. Amps 5.2-4.8 F.L. Amps 2.4 F.L. Amps
S. F Amps S. F Amps S. F Amps
RPM 3600 Hertz 60
HP 2 Duty CONTINUOUS
TYPE TF KW 1.49
Frame 56C Serv. Factor 1.0
Phase 3 Max Amb 40
Design B Code L
Insul Class F Protection NOT
Therm.Prot.
Eff 100% 85.5 Eff 75%
PF 88
UL Y-(LEESON UL REC) CSA Yes Bearing OPE 6203
CC Number EXEMPT CE Yes Bearing PE 6205
Load Type Inverter Type Speed Range NONE
Motor Wt. 41 LB
Enclosure TEFC
Lubrication POLYREX EM
Nameplate 081341
Mounting ROUND
Rotation REV
Assembly NONE
Shaft Dia. 5/8 IN
Ext. Diag. 005010.20
Cust Part No
Outline 607-0006-750
Ext. Diag2 Packaging B
Winding T632174 Carton Label Leeson Washguard
GROUP: 3
Iris
Paint WHITE - LEESON (EPOXY) Test Card 02
Form Factor RMS Amps Const Torque Speed Range
Torque Peak AB Code
Peak@DegC
Resistance Connection
Rework Status Rework TYPE
Hazardous Loc NONE Brake Motors
Explosion Proof Temp Op Code FORCE
Class GROUP: VDC
Class GROUP: ADC
Brake Coil OHMs @25 C
Performance Torque UOM LB-FT Inertia (WK²) .08 LB-FT^2
Torque 3(Full Load) 13(Break Down) 10.5(Pull Up) 10.8(Locked Rotor)
CURRENT (amps) 2.4(Full Load) 0(Break Down) 0(Pull Up) 26(Locked Rotor)
Efficiency (%) 0(Full Load) 86.7(75% Load) 85.5(50% Load) 97.6(25% Load)
PowerFactor 0(Full Load) 82.1(75% Load) 72.2(50% Load) 44.6(25% Load)
Load Curve Data @60 Hz, 460 Volts, 2 Horsepower
Load Amps KW RPM Torque EFF PF Rise By Resis Frame Rise
0.0 0.95 0.127 3598 0.0 0.0 16.8 0.0
0.25 1.1 0.391 3581 0.75 97.6 44.6 0.0
0.5 1.54 0.886 3555 1.5 85.5 72.2 0.0
0.75 1.99 1.302 3533 2.25 86.7 82.1 0.0
1.0 2.44 1.718 3511 3.0 87.1 88.4 46.0 18.0
1.25 2.99 2.128 3487 3.75 87.3 89.3 0.0
1.5 3.55 2.562 3460 4.5 86.3 90.6 0.0
-
SOURCE: CALCULATED GROUP: 3