Skip to product information
1 of 1

Industrial Motors

Leeson Electric 122187.00, 1 1/2 HP, 1800 RPM, 145JM FR, 208-230/460 Vac, 3 PH, TEFC, JM Pump, Washdown Duty Pump

Leeson Electric 122187.00, 1 1/2 HP, 1800 RPM, 145JM FR, 208-230/460 Vac, 3 PH, TEFC, JM Pump, Washdown Duty Pump

Regular price $1,591.00
Regular price Sale price $1,591.00
Add to Cart for Discount
Sale Sold out
Shipping calculated at checkout.
$1,591.00 $859.14
Sale
Quantity

122187.00, 1 1/2 HP, 1800 RPM, 145JM FR, 208-230/460 Vac, 3 PH, TEFC, JM Pump, Washdown Duty Pump

Engineering Data

Volts 208-230 Volts 460 Volts 190/380
F.L. Amps 4.6-4.8 F.L. Amps 2.4 F.L. Amps 5.56-5.6/2.8
S. F Amps 5.2-5.4 S. F Amps 2.7 S. F Amps 6.12-6/3

--------------------------------------------------------------------------------

RPM 1800 Hertz 60/50
HP 1 1/2 Duty CONTINUOUS TYPE TF
KW 1.12
Frame 145JM Serv. Factor 1.15 Phase 3
Max Amb 40 Design B Code L
Insul Class F Protection NOT Therm.Prot.
Eff 100% 86.5 Eff 75% PF 67.7
UL Yes CSA Yes Bearing OPE 6203
CC Number CC005A CE Yes Bearing PE 6206
Load Type Inverter Type Speed Range NONE

--------------------------------------------------------------------------------

Motor Wt. 39 LB Enclosure TEFC Lubrication POLYREX EM
Nameplate 081341 Mounting RIGID Rotation REV
Assembly NONE Shaft Dia. 1 5/8 IN Ext. Diag. 005010.02
Cust Part No Outline 607-0013-750 Ext. Diag2
Packaging B Outline Dash No Winding T84176
Carton Label Leeson Washguard GROUP: 3
Iris Paint White-Leeson (EPOXY) Test Card 03

--------------------------------------------------------------------------------

Form Factor RMS Amps Const Torque Speed Range
Torque Peak
AB Code Peak@DegC
Resistance
Connection

--------------------------------------------------------------------------------

Rework Status Rework TYPE

--------------------------------------------------------------------------------

Hazardous Loc NONE Brake Motors
Explosion Proof Temp Op Code FORCE
Class GROUP: VDC
Class GROUP: ADC
Brake Coil OHMs @25 C
Performance
Torque UOM LB-FT Inertia (WK²) .38 LB-FT^2
Torque 4.5(Full Load) 20.4(Break Down) 17(Pull Up) 17.2(Locked Rotor)
CURRENT (amps) 2.4(Full Load) 12.09(Break Down) 16.06(Pull Up) 18.5(Locked Rotor)
Efficiency (%) 0(Full Load) 87.2(75% Load) 84.2(50% Load) 74.4(25% Load)
PowerFactor 75.3(Full Load) 67.3(75% Load) 55.2(50% Load) 35.4(25% Load)

Load Curve Data @60/50 Hz, 460 Volts, 3 Horsepower
Load Amps KW RPM Torque Eff PF Rise By Resis Frame Rise
0.0 1.23 0.097 1797 0.0 0.0 9.9 0.0 -
0.25 1.33 0.375 1786 1.1 74.4 35.4 0.0 -
0.5 1.53 0.673 1773 2.25 84.2 55.2 0.0 -
0.75 1.81 0.97 1761 3.38 87.2 67.3 0.0 -
1.0 2.15 1.291 1746 4.5 86.5 75.4 45.0 -
1.25 2.52 1.611 1732 5.63 86.0 80.2 65.0 -
1.5 2.94 1.945 1716 6.75 84.6 83.0 65.0 -
1.75 3.37 2.286 1699 7.88 83.2 85.1 0.0 -
2.0 3.85 2.65 1678 9.0 80.9 86.4 0.0 -
SOURCE: CALCULATED GROUP: 3




1051 Cheyenne Ave, Grafton, WI 53024
Email: leebizsupport@leeson.com Terms and Conditions Copyright © Regal-Beloit Corporation 2014