Industrial Motors
Couldn't load pickup availability
E119352.00, 1/2 Hp, 1800 Rpm, 56C FR, DP, 208-230/460 Vac, 3 PH, C-Face Less Base, General Purpose.
Engineering Data
Volts 230 Volts 460 Volts 190/380
F.L. Amps 2 F.L. Amps 1 F.L. Amps 2/1
S. F Amps 2.2 S. F Amps 1.1 S. F Amps 2.2/1.1
RPM 1800 Hertz 60/50
HP 1/2 Duty CONTINUOUS TYPE TD
KW 0.37
Frame 56C Serv. Factor 1.25 Phase 3
Max Amb 40 Design B Code N
Insul Class F Protection NOT Therm.Prot. 9700K46
Eff 100% 78.2 Eff 75% PF 62.9
UL Y-(LEESON UL REC) CSA Yes Bearing OPE 6203
CC Number EXEMPT CE Yes Bearing PE 6203
Load Type Inverter Type Speed Range 1.1 X BASE SPEED
Motor Wt. 22.6 LB Enclosure DP Lubrication STANDARD
Nameplate 10000418-001-001 Mounting ROUND Rotation REV
Assembly Shaft Dia. 5/8 IN Ext. Diag. 005010.20
Cust Part No Outline 607-0192-500 Ext. Diag2
Packaging B Outline Dash No Winding T634467
Carton Label Individual Leeson ECOSaver GROUP : 3
Iris Paint GREEN - LEESON WATTSAVER Test Card 01
Form Factor RMS Amps Const Torque Speed Range
Torque Peak
AB Code Peak@DegC
Resistance
Connection
Rework Status Rework TYPE
Hazardous Loc NONE Brake Motors
Explosion Proof Temp Op Code FORCE
Class GROUP : VDC
Class GROUP : ADC
Brake Coil OHMs @25 C
Performance
Torque UOM OZ-FT Inertia (WK²) .054 LB-FT^2
Torque 23.88(Full Load) 109.48(Break Down) 84.27(Pull Up) 83.35(Locked Rotor)
CURRENT (amps) .93(Full Load) 4.72(Break Down) 6.63(Pull Up) 6.71(Locked Rotor)
Efficiency (%) 0(Full Load) 77.2(75% Load) 72.5(50% Load) 59.4(25% Load)
PowerFactor 0(Full Load) 53.6(75% Load) 41.4(50% Load) 27(25% Load)
Load Curve Data @60/50 Hz , 380 Volts , 1/2 Horsepower
Load Amps KW2 RPM Torque EFF PF Rise By Resis Frame Rise
0.0 0.72 0.077 1796 0.0 0.0 13.4 0.0 -
0.25 0.73 0.157 1790 5.88 59.4 27.0 0.0 -
0.5 0.78 0.257 1780 11.78 72.5 41.4 0.0 -
0.75 0.85 0.362 1770 17.79 77.2 53.6 0.0 -
1.0 0.93 0.468 1759 23.88 79.6 62.9 21.3 -
1.25 1.04 0.578 1746 30.07 80.6 69.9 0.0 -
1.5 1.16 0.694 1733 36.35 80.6 75.0 0.0 -