Industrial Motors
Couldn't load pickup availability
Engineering Data
Volts 575 Volts Volts
F.L. Amps 97.5 F.L. Amps F.L. Amps
S. F Amps 110 S. F Amps S. F Amps
--------------------------------------------------------------------------------
RPM 1800 Hertz 60
HP 100 Duty CONTINUOUS TYPE TFR
KW 74.6
Frame 405TC Serv. Factor 1.15 Phase 3
Max Amb 40 Design B Code G
Insul Class F Protection NOT Therm.Prot.
Eff 100% 95.4 Eff 75% PF 80.5
UL V-INS, CONST UL REC CSA Yes Bearing OPE 313
CC Number CC004A CE Yes Bearing PE 315
Load Type Inverter Type NONE Speed Range NONE
--------------------------------------------------------------------------------
Motor Wt. 1001 LB Enclosure TEFC Lubrication STANDARD
Nameplate 3B451-AZ-X-ABCD-D-A Mounting RIGID Rotation REV
Assembly Shaft Dia. Ext. Diag. A-EE7340-LN
Cust Part No Outline XJ2F1SC1-1946 Ext. Diag2
Packaging B Outline Dash No Winding L4054027
Carton Label GROUP: 2
Iris Paint GRAY - LINCOLN Test Card
--------------------------------------------------------------------------------
Form Factor RMS Amps Const Torque Speed Range
Torque Peak
AB Code Peak@DegC
Resistance
Connection
--------------------------------------------------------------------------------
Rework Status Rework TYPE
--------------------------------------------------------------------------------
Hazardous Loc NONE Brake Motors
Explosion Proof Temp Op Code FORCE
Class GROUP: VDC
Class GROUP: ADC
Brake Coil OHMs @25 C
Performance
Torque UOM Inertia (WK²)
Torque
CURRENT (amps)
Efficiency (%)
PowerFactor
Load Curve Data @60 Hz, 575 Volts, 100 Horsepower
Load Amps KW RPM Torque Eff PF Rise By Resis Frame Rise
0.0 49.0 1.5 1800 0.0 0.0 3.0 0.0 -
0.25 58.5 20.0 1795 73.0 91.7 43.5 0.0 -
0.5 75.0 39.0 1792 147.0 95.0 66.0 0.0 -
0.75 96.5 58.5 1788 220.0 95.4 76.0 0.0 -
1.0 122.0 78.0 1785 294.0 95.4 80.5 65.0 -
1.15 138.0 90.0 1782 339.0 95.4 81.5 85.0 -
1.25 150.0 98.0 1780 369.0 95.0 82.0 100.0 -
SOURCE CALCULATED GROUP 2