Industrial Motors
Couldn't load pickup availability
Engineering Data
Volts 460 Volts Volts
F.L. Amps 17.5 F.L. Amps F.L. Amps
S. F Amps None S. F Amps S. F Amps
--------------------------------------------------------------------------------
RPM 3600 Hertz 60
HP 15 Duty CONTINUOUS TYPE TFS
KW 11.19
Frame 256U Serv. Factor 1.0 Phase 3
Max Amb 65 Design B Code G
Insul Class F Protection NOT Therm.Prot.
Eff 100% 91.7 Eff 75% PF 85
UL V-INS, CONST UL REC CSA Yes Bearing OPE 210
CC Number CC004A CE Yes Bearing PE 309
Load Type Inverter Type NONE Speed Range NONE
--------------------------------------------------------------------------------
Motor Wt. 316 LB Enclosure TEFC Lubrication STANDARD
Nameplate Mounting RIGID Rotation REV
Assembly Shaft Dia. Ext. Diag. A-EE7300-LN
Cust Part No Outline SS203362LN-1225 Ext. Diag2
Packaging B Outline Dash No Winding K256289
Carton Label GROUP: 7
Iris Paint LINCOLN GRAY Test Card
--------------------------------------------------------------------------------
Form Factor RMS Amps Const Torque Speed Range
Torque Peak
AB Code Peak@DegC
Resistance
Connection
--------------------------------------------------------------------------------
Rework Status Rework TYPE
--------------------------------------------------------------------------------
Hazardous Loc NONE Brake Motors
Explosion Proof Temp Op Code FORCE
Class GROUP: VDC
Class GROUP: ADC
Brake Coil OHMs @25 C
Performance
Torque UOM Inertia (WK²)
Torque
CURRENT (amps)
Efficiency (%)
PowerFactor
Load Curve Data @60 Hz, 460 Volts, 15 Horsepower
Load Amps KW RPM Torque Eff PF Rise By Resis Frame Rise
0.0 6.0 1.5 3600 0.0 0.0 10.5 0.0 -
0.25 7.5 3.5 3585 5.5 85.5 56.0 30.0 -
0.5 10.0 6.0 3570 11.0 90.2 75.5 25.0 -
0.75 14.0 9.0 3560 16.5 91.7 83.5 0.0 -
1.0 17.5 12.0 3550 22.2 91.7 85.0 50.0 -
1.15 20.0 13.0 3540 25.0 91.7 87.0 70.0 -
1.25 22.0 15.5 3525 28.0 91.0 88.0 85.0