Industrial Motors
Couldn't load pickup availability
Engineering Data
Volts 460 Volts Volts
F.L. Amps 47 F.L. Amps F.L. Amps
S. F Amps None S. F Amps S. F Amps
--------------------------------------------------------------------------------
RPM 1800 Hertz 60
HP 40 Duty CONTINUOUS TYPE TFS
KW 29.8
Frame 364U Serv. Factor 1.0 Phase 3
Max Amb 65 Design B Code F
Insul Class F Protection NOT Therm.Prot.
Eff 100% 94.1 Eff 75% PF 86
UL V-INS, CONST UL REC CSA Yes Bearing OPE 312
CC Number CC004A CE Yes Bearing PE 314
Load Type Inverter Type Speed Range NONE
--------------------------------------------------------------------------------
Motor Wt. 977 LB Enclosure TEFC Lubrication STANDARD
Nameplate Mounting RIGID Rotation REV
Assembly Shaft Dia. Ext. Diag. A-EE7300-LN
Cust Part No Outline B-SS518366LN-1350 Ext. Diag2
Packaging B Outline Dash No Winding T3644143
Carton Label GROUP: 1
Iris Paint LINCOLN GRAY Test Card
--------------------------------------------------------------------------------
Form Factor RMS Amps Const Torque Speed Range
Torque Peak
AB Code Peak@DegC
Resistance
Connection
--------------------------------------------------------------------------------
Rework Status Rework TYPE
--------------------------------------------------------------------------------
Hazardous Loc NONE Brake Motors
Explosion Proof Temp Op Code FORCE
Class GROUP: VDC
Class GROUP: ADC
Brake Coil OHMs @25 C
Performance
Torque UOM Inertia (WK²)
Torque
CURRENT (amps)
Efficiency (%)
PowerFactor
Load Curve Data @60 Hz, 460 Volts, 40 Horsepower
Load Amps KW RPM Torque Eff PF Rise By Resis Frame Rise
0.0 14.0 0.75 1800 0.0 0.0 5.5 0.0 -
0.25 17.8 8.2 1795 29.3 91.0 58.0 0.0 -
0.5 25.5 16.0 1790 58.8 94.1 77.0 0.0 -
0.75 35.5 23.8 1785 88.5 94.5 84.0 0.0 -
1.0 46.5 31.8 1780 118.0 94.1 86.0 55.0 -
1.15 53.5 36.6 1775 136.0 93.6 86.5 75.0 -
1.25 58.5 40.0 1772 148.0 93.0 86.5 90.0