Industrial Motors
Couldn't load pickup availability
Engineering Data
Volts 230 Volts 460 Volts
F.L. Amps 5 F.L. Amps 2.5 F.L. Amps
S. F Amps None S. F Amps S. F Amps
--------------------------------------------------------------------------------
RPM 1800 Hertz 60
HP 1 1/2 Duty CONTINUOUS TYPE TS
KW 1.12
Frame 56HC Serv. Factor 1.0 Phase 3
Max Amb 40 Design B Code M
Insul Class F Protection NOT Therm.Prot.
Eff 100% 78.5 Eff 75% PF 74.5
UL V-OVER TEMP PROT 3, P1-P2 CSA Yes Bearing OPE 203
CC Number CE Yes Bearing PE 205
Load Type Inverter Type NONE Speed Range NONE
--------------------------------------------------------------------------------
Motor Wt. 41 LB Enclosure TEFC Lubrication STANDARD
Nameplate Mounting RIGID Rotation REV
Assembly Shaft Dia. Ext. Diag. A-EE7308T-LN
Cust Part No Outline A-100109LN-806 Ext. Diag2
Packaging B Outline Dash No Winding ZT4137
Carton Label GROUP: 3
Iris Paint UNK Test Card
--------------------------------------------------------------------------------
Form Factor RMS Amps Const Torque Speed Range
Torque Peak
AB Code Peak@DegC
Resistance
Connection
--------------------------------------------------------------------------------
Rework Status Rework TYPE
--------------------------------------------------------------------------------
Hazardous Loc NONE Brake Motors
Explosion Proof Temp Op Code FORCE
Class GROUP: VDC
Class GROUP: ADC
Brake Coil OHMs @25 C
Performance
Torque UOM Inertia (WK²)
Torque
CURRENT (amps)
Efficiency (%)
PowerFactor
Load Curve Data @60 Hz, 460 Volts, 1 1/2 Horsepower
Load Amps KW RPM Torque Eff PF Rise By Resis Frame Rise
0.0 1.55 0.2 1800 0.0 0.0 16.0 0.0 -
0.25 1.6 0.48 1785 1.1 58.5 37.5 0.0 -
0.5 1.8 0.78 1770 2.2 71.5 54.4 0.0 -
0.75 2.1 1.1 1760 3.4 76.5 66.0 0.0 -
1.0 2.5 1.4 1740 4.5 78.5 74.5 60.0 -
1.25 2.8 1.8 1730 5.7 79.0 79.5 0.0 -
1.5 - 0.0 0 0.0 0.0 0.0 0.0 -
2.0 - 0.0 0 0.0 0.0 0.0 0.0 -
1.0 2.5 1.4 1740 4.5 0.0 0.0 0.0