Industrial Motors
Couldn't load pickup availability
Engineering Data
Volts 460 Volts Volts
F.L. Amps 460 F.L. Amps F.L. Amps
S. F Amps S. F Amps S. F Amps
--------------------------------------------------------------------------------
RPM 1800 Hertz 60
HP 400 Duty CONTINUOUS TYPE TDR
KW 298.4
Frame 449TS Serv. Factor 1.0 Phase 3
Max Amb 40 Design BC Code G
Insul Class F Protection NOT Therm.Prot.
Eff 100% 95.8 Eff 75% PF 85
UL V-INS, CONST UL REC CSA Yes Bearing OPE 315
CC Number CC004A CE Yes Bearing PE 318
Load Type Inverter Type NONE Speed Range NONE
--------------------------------------------------------------------------------
Motor Wt. 2112 LB Enclosure DP Lubrication STANDARD
Nameplate 3B451-A-X-ABCD-E-A-X Mounting RIGID Rotation REV
Assembly Shaft Dia. Ext. Diag. A-EE7340-LN
Cust Part No Outline XK2D1SS2-3177 Ext. Diag2
Packaging B Outline Dash No Winding L4494037
Carton Label GROUP: 1
Iris Paint STANDARD Test Card
--------------------------------------------------------------------------------
Form Factor RMS Amps Const Torque Speed Range
Torque Peak
AB Code Peak@DegC
Resistance
Connection
--------------------------------------------------------------------------------
Rework Status Rework TYPE
--------------------------------------------------------------------------------
Hazardous Loc NONE Brake Motors
Explosion Proof Temp Op Code FORCE
Class GROUP: VDC
Class GROUP: ADC
Brake Coil OHMs @25 C
Performance
Torque UOM Inertia (WK²)
Torque
CURRENT (amps)
Efficiency (%)
PowerFactor
Load Curve Data @60 Hz, 460 Volts, 400 Horsepower
Load Amps KW RPM Torque Eff PF Rise By Resis Frame Rise
0.0 120.0 3.0 1800 0.0 0.0 3.0 0.0 -
0.25 164.0 78.5 1795 292.0 95.0 60.0 0.0 -
0.5 246.0 155.0 1792 586.0 96.5 79.0 0.0 -
0.75 349.0 232.0 1788 881.0 96.2 83.5 0.0 -
1.0 460.0 311.0 1783 1178.0 95.8 85.0 100.0 -
1.15 531.0 359.0 1780 1357.0 95.4 85.0 0.0 -
1.25 - 392.0 1778 1477.0 95.0 84.5 0.0