Industrial Motors
Couldn't load pickup availability
Engineering Data
Volts 208-230 Volts 460 Volts
F.L. Amps 6.4-6.2 F.L. Amps 3.1 F.L. Amps
S. F Amps 7.1-6.9 S. F Amps 3.45 S. F Amps
--------------------------------------------------------------------------------
RPM 3600 Hertz 60
HP 2 Duty CONTINUOUS TYPE TS
KW 1.492
Frame 56HC Serv. Factor 1.15 Phase 3
Max Amb 40 Design B Code J
Insul Class F Protection NOT Therm.Prot.
Eff 100% 80 Eff 75% PF
UL V-INS, CONST UL REC CSA Yes Bearing OPE 203
CC Number EXEMPT CE Bearing PE 203
Load Type Inverter Type NONE Speed Range NONE
--------------------------------------------------------------------------------
Motor Wt. 27 LB Enclosure DP Lubrication STANDARD
Nameplate Mounting RIGID Rotation REV
Assembly Shaft Dia. Ext. Diag. A-EE7308-LN
Cust Part No Outline A-104723LN-656 Ext. Diag2
Packaging B Outline Dash No Winding ZT202
Carton Label GROUP: 3
Iris Paint STANDARD Test Card
--------------------------------------------------------------------------------
Form Factor RMS Amps Const Torque Speed Range
Torque Peak
AB Code Peak@DegC
Resistance
Connection
--------------------------------------------------------------------------------
Rework Status Rework TYPE
--------------------------------------------------------------------------------
Hazardous Loc NONE Brake Motors
Explosion Proof Temp Op Code FORCE
Class GROUP: VDC
Class GROUP: ADC
Brake Coil OHMs @25 C
Performance
Torque UOM Inertia (WK²)
Torque
CURRENT (amps)
Efficiency (%)
PowerFactor
Load Curve Data @60 Hz, Volts, 2 Horsepower
Load Amps KW RPM Torque Eff PF Rise By Resis Frame Rise