Industrial Motors
Couldn't load pickup availability
Engineering Data
Volts 230 Volts 460 Volts
F.L. Amps 6 F.L. Amps 3 F.L. Amps
S. F Amps 6.4 S. F Amps 3.2 S. F Amps
--------------------------------------------------------------------------------
RPM 3600 Hertz 60
HP 2 Duty CONTINUOUS TYPE TS
KW 1.49
Frame 56C Serv. Factor 1.15 Phase 3
Max Amb 40 Design B Code L
Insul Class F Protection NOT Therm.Prot.
Eff 100% 80 Eff 75% PF 76.5
UL V-INS, CONST UL REC CSA Yes Bearing OPE 203
CC Number EXEMPT CE Bearing PE 203
Load Type Inverter Type Speed Range NONE
--------------------------------------------------------------------------------
Motor Wt. Enclosure TEFC Lubrication STANDARD
Nameplate Mounting RIGID Rotation REV
Assembly Shaft Dia. Ext. Diag. A-EE7308-LN
Cust Part No Outline A-100109LN-706 Ext. Diag2
Packaging B Outline Dash No Winding ZT217
Carton Label GROUP: 3
Iris Paint LINCOLN GRAY Test Card
--------------------------------------------------------------------------------
Form Factor RMS Amps Const Torque Speed Range
Torque Peak
AB Code Peak@DegC
Resistance
Connection
--------------------------------------------------------------------------------
Rework Status Rework TYPE
--------------------------------------------------------------------------------
Hazardous Loc NONE Brake Motors
Explosion Proof Temp Op Code FORCE
Class GROUP: VDC
Class GROUP: ADC
Brake Coil OHMs @25 C
Performance
Torque UOM Inertia (WK²)
Torque
CURRENT (amps)
Efficiency (%)
PowerFactor
Load Curve Data @60 Hz, 460 Volts, 2 Horsepower
Load Amps KW RPM Torque Eff PF Rise By Resis Frame Rise
0.0 1.8 0.18 3600 0.0 0.0 13.0 0.0 -
0.25 2.0 0.57 3575 0.73 66.0 37.5 0.0 -
0.5 2.2 0.97 3550 1.5 77.0 56.5 0.0 -
0.75 2.5 1.4 3525 2.2 81.5 69.0 0.0 -
1.0 3.0 1.8 3495 3.0 80.0 76.5 65.0 -
1.15 3.2 2.1 3485 3.5 80.0 80.0 85.0 -
1.25 3.4 2.2 3475 3.8 80.0 81.5 0.0