Engineering Data
Volts 230 Volts 460 Volts
F.L. Amps 64 F.L. Amps 32 F.L. Amps
S. F Amps S. F Amps S. F Amps
--------------------------------------------------------------------------------
RPM 1200 Hertz 60
HP 25 Duty SPECIAL TYPE TDR
KW 18.7
Frame 324TC Serv. Factor 1.0 Phase 3
Max Amb 40 Design SPECIAL Code K
Insul Class F Protection NOT Therm.Prot.
Eff 100% 91 Eff 75% PF 80
UL V-OVER TEMP PROT 3, P1-P2 CSA Yes Bearing OPE 309
CC Number EXEMPT CE Yes Bearing PE 311
Load Type Inverter Type Speed Range NONE
--------------------------------------------------------------------------------
Motor Wt. 499 LB Enclosure DP Lubrication STANDARD
Nameplate Mounting ROUND Rotation REV
Assembly Shaft Dia. Ext. Diag. A-EE7358-LN
Cust Part No Outline XG3D1EC33B-1507 Ext. Diag2
Packaging B Outline Dash No Winding L3246016
Carton Label GROUP: 1
Iris Paint LINCOLN GRAY Test Card
--------------------------------------------------------------------------------
Form Factor RMS Amps Const Torque Speed Range
Torque Peak
AB Code Peak@DegC
Resistance
Connection
--------------------------------------------------------------------------------
Rework Status Rework TYPE
--------------------------------------------------------------------------------
Hazardous Loc NONE Brake Motors
Explosion Proof Temp Op Code FORCE
Class GROUP: VDC
Class GROUP: ADC
Brake Coil OHMs @25 C
Performance
Torque UOM Inertia (WK²)
Torque
CURRENT (amps)
Efficiency (%)
PowerFactor
Load Curve Data @60 Hz, 460 Volts, 25 Horsepower
Load Amps KW RPM Torque Eff PF Rise By Resis Frame Rise
0.0 15.0 1.0 1200 0.0 0.0 7.5 0.0 -
0.25 17.0 5.5 1196 27.5 82.5 41.0 0.0 -
0.5 20.5 10.5 1193 55.0 89.5 63.0 0.0 -
0.75 26.0 15.5 1189 83.0 90.2 74.0 0.0 -
1.0 32.0 20.5 1185 111.0 91.0 80.0 100.0 -
1.25 38.5 25.5 1181 140.0 90.2 83.0 0.0 -
2.0 62.0 41.5 1165 220.0 88.5 84.0 0.0 -
2.5 82.0 53.0 1150 275.0 85.0 81.5 0.0 -
1.0 32.0 20.5 1185 111.0 0.0 0.0 0.0