Industrial Motors
Couldn't load pickup availability
Engineering Data
Volts 230 Volts 460 Volts
F.L. Amps 304 F.L. Amps 152 F.L. Amps
S. F Amps S. F Amps S. F Amps
--------------------------------------------------------------------------------
RPM 1800 Hertz 60
HP 125 Duty CONTINUOUS TYPE TDR
KW 93.0
Frame 405T Serv. Factor 1.0 Phase 3
Max Amb 40 Design B Code G
Insul Class F Protection NOT Therm.Prot.
Eff 100% 95.4 Eff 75% PF 81.5
UL V-INS, CONST UL REC CSA Yes Bearing OPE 6313
CC Number CC004A CE Yes Bearing PE 6315
Load Type Inverter Type Speed Range NONE
--------------------------------------------------------------------------------
Motor Wt. 942 LB Enclosure DP Lubrication STANDARD
Nameplate 3B452-AZ-X-BCDLM-B-X Mounting RIGID Rotation REV
Assembly Shaft Dia. Ext. Diag. A-EE7308BZ-LN
Cust Part No Outline XJ2D1SS1-1885 Ext. Diag2
Packaging B Outline Dash No Winding L4054043
Carton Label GROUP: 1
Iris Paint LINCOLN GRAY Test Card
--------------------------------------------------------------------------------
Form Factor RMS Amps Const Torque Speed Range
Torque Peak
AB Code Peak@DegC
Resistance
Connection
--------------------------------------------------------------------------------
Rework Status Rework TYPE
--------------------------------------------------------------------------------
Hazardous Loc NONE Brake Motors
Explosion Proof Temp Op Code FORCE
Class GROUP: VDC
Class GROUP: ADC
Brake Coil OHMs @25 C
Performance
Torque UOM Inertia (WK²)
Torque
CURRENT (amps)
Efficiency (%)
PowerFactor
Load Curve Data @60 Hz, 460 Volts, 125 Horsepower
Load Amps KW RPM Torque Eff PF Rise By Resis Frame Rise
0.0 61.0 2.4 1800 0.0 0.0 2.5 0.0 -
0.25 70.5 25.5 1795 91.5 92.4 44.5 0.0 -
0.5 92.0 49.5 1792 183.0 95.0 67.0 0.0 -
0.75 120.0 74.0 1788 275.0 95.4 77.0 0.0 -
1.0 152.0 98.0 1783 368.0 95.4 81.5 50.0 -
1.15 173.0 114.0 1780 424.0 95.0 82.5 70.0 -
1.25 188.0 124.0 1778 462.0 94.5 82.5 85.0 -