Engineering Data
Volts 200 Volts 400 Volts
F.L. Amps 147 F.L. Amps 73.5 F.L. Amps
S. F Amps 159 S. F Amps 79.5 S. F Amps
--------------------------------------------------------------------------------
RPM 1800 Hertz 60
HP 40 Duty CONTINUOUS TYPE TDR
KW 30
Frame 324T Serv. Factor 1.15 Phase 3
Max Amb 40 Design A Code J
Insul Class F Protection NOT Therm.Prot.
Eff 100% 93 Eff 75% PF 63
UL V-INS, CONST UL REC CSA Yes Bearing OPE 309
CC Number CC004A CE Yes Bearing PE 311
Load Type Inverter Type Speed Range NONE
--------------------------------------------------------------------------------
Motor Wt. 491 LB Enclosure DP Lubrication STANDARD
Nameplate 3B451-A-X-BCDLM-B-A-X Mounting RIGID Rotation REV
Assembly Shaft Dia. Ext. Diag. A-EE7308AA-LN
Cust Part No Outline XG2D1SS1-1507 Ext. Diag2
Packaging B Outline Dash No Winding L3244042
Carton Label GROUP: 2
Iris Paint LINCOLN GRAY Test Card
--------------------------------------------------------------------------------
Form Factor RMS Amps Const Torque Speed Range
Torque Peak
AB Code Peak@DegC
Resistance
Connection
--------------------------------------------------------------------------------
Rework Status Rework TYPE
--------------------------------------------------------------------------------
Hazardous Loc NONE Brake Motors
Explosion Proof Temp Op Code FORCE
Class GROUP: VDC
Class GROUP: ADC
Brake Coil OHMs @25 C
Performance
Torque UOM Inertia (WK²)
Torque
CURRENT (amps)
Efficiency (%)
PowerFactor
Load Curve Data @60 Hz, 400 Volts, 40 Horsepower
Load Amps KW RPM Torque Eff PF Rise By Resis Frame Rise
0.0 42.0 1.4 1800 0.0 0.0 4.0 0.0 -
0.25 44.0 8.5 1796 29.5 82.5 24.5 0.0 -
0.5 49.0 16.0 1793 58.5 90.2 42.0 0.0 -
0.75 55.0 24.0 1789 88.0 91.7 54.0 0.0 -
1.0 64.0 32.0 1785 118.0 93.0 63.0 55.0 -
1.15 69.0 36.0 1783 135.0 93.0 66.5 0.0 -
1.25 73.0 40.0 1781 148.0 93.0 68.0 0.0