Industrial Motors
Couldn't load pickup availability
Engineering Data
Volts 230 Volts 460 Volts 190/380
F.L. Amps 226 F.L. Amps 113 F.L. Amps 208/104
S. F Amps 260 S. F Amps 130 S. F Amps
--------------------------------------------------------------------------------
RPM 1800 Hertz 60/50
HP 100 Duty CONTINUOUS TYPE TFS
KW 75
Frame 405T Serv. Factor 1.15 Phase 3
Max Amb 40 Design B Code G
Insul Class F Protection NOT Therm.Prot.
Eff 100% 95.4 Eff 75% PF 87.5
UL V-INS, CONST UL REC CSA Yes Bearing OPE 6313
CC Number CC004A CE Yes Bearing PE 6316
Load Type Inverter Type Speed Range NONE
--------------------------------------------------------------------------------
Motor Wt. Enclosure TEFC Lubrication STANDARD
Nameplate 92237-AZ-CFL-BCDLM-B-A-X Mounting RIGID Rotation REV
Assembly Shaft Dia. Ext. Diag. A-EE7308AA-LN
Cust Part No Outline B-SS508859LN-1675 Ext. Diag2
Packaging N Outline Dash No Winding T4054176
Carton Label GROUP: 1
Iris Paint STANDARD Test Card
--------------------------------------------------------------------------------
Form Factor RMS Amps Const Torque Speed Range
Torque Peak
AB Code Peak@DegC
Resistance
Connection
--------------------------------------------------------------------------------
Rework Status Rework TYPE
--------------------------------------------------------------------------------
Hazardous Loc NONE Brake Motors
Explosion Proof Temp Op Code FORCE
Class GROUP: VDC
Class GROUP: ADC
Brake Coil OHMs @25 C
Performance
Torque UOM Inertia (WK²)
Torque
CURRENT (amps)
Efficiency (%)
PowerFactor
Load Curve Data @60/50 Hz, 460 Volts, 100 Horsepower
Load Amps KW RPM Torque Eff PF Rise By Resis Frame Rise
0.0 31.5 1.4 1800 0.0 0.0 2.5 0.0 -
0.25 41.5 20.0 1795 73.0 94.1 59.5 0.0 -
0.5 62.0 39.0 1790 147.0 95.8 79.0 0.0 -
0.75 86.0 60.0 1785 221.0 95.8 85.5 0.0 -
1.0 113.0 79.0 1780 295.0 95.4 87.5 80.0 -
1.15 130.0 91.0 1775 340.0 95.0 87.5 105.0 -
1.25 142.0 99.0 1775 370.0 94.5 87.5 0.0