Industrial Motors
Couldn't load pickup availability
OBSOLETE, REPLACED BY 199044.00
Engineering Data
Volts 460 Volts Volts 380
F.L. Amps 142 F.L. Amps F.L. Amps 138
S. F Amps 165 S. F Amps S. F Amps 160
--------------------------------------------------------------------------------
RPM 1200 Hertz 60/50
HP 125 Duty CONTINUOUS TYPE TF
KW 93
Frame 445T Serv. Factor 1.15 Phase 3
Max Amb 40 Design B Code G
Insul Class F Protection NOT Therm.Prot.
Eff 100% 95 Eff 75% PF 86
UL Y-(LEESON UL REC) CSA Yes Bearing OPE 6317
CC Number CC005A CE No Bearing PE 6319
Load Type Inverter Type Speed Range NONE
--------------------------------------------------------------------------------
Motor Wt. 2081 LB Enclosure TEFC Lubrication STANDARD
Nameplate 93405-L-N-ABDEF-D-D Mounting RIGID Rotation REV
Assembly Shaft Dia. Ext. Diag. A-EE7341C-LE
Cust Part No Outline B-SS620287 Ext. Diag2
Packaging F Outline Dash No Winding CHT44560001
Carton Label GROUP: 2
Iris Paint GRAY ENAMEL Test Card
--------------------------------------------------------------------------------
Form Factor RMS Amps Const Torque Speed Range
Torque Peak
AB Code Peak@DegC
Resistance
Connection
--------------------------------------------------------------------------------
Rework Status Rework TYPE
--------------------------------------------------------------------------------
Hazardous Loc NONE Brake Motors
Explosion Proof Temp Op Code FORCE
Class GROUP: VDC
Class GROUP: ADC
Brake Coil OHMs @25 C
Performance
Torque UOM Inertia (WK²)
Torque
CURRENT (amps)
Efficiency (%)
PowerFactor
Load Curve Data @60/50 Hz, 460 Volts, 125 Horsepower
Load Amps KW RPM Torque Eff PF Rise By Resis Frame Rise
0.0 37.5 2.5 1200 0.0 0.0 5.0 0.0 -
0.25 50.0 25.0 1196 137.0 92.4 63.0 0.0 -
0.5 77.0 49.0 1194 274.0 94.5 80.0 0.0 -
0.75 108.0 73.5 1192 413.0 95.0 85.0 0.0 -
1.0 142.0 98.0 1188 552.0 95.0 86.0 75.0 -
1.15 165.0 113.0 1186 636.0 95.0 86.0 105.0 -
1.25 180.0 123.0 1184 693.0 94.5 86.0 0.0