Industrial Motors
Couldn't load pickup availability
Engineering Data
Volts 230 Volts 460 Volts 190/380
F.L. Amps 123 F.L. Amps 61.5 F.L. Amps 120/60
S. F Amps 140 S. F Amps 70 S. F Amps 137/68.5
--------------------------------------------------------------------------------
RPM 1800 Hertz 60/50
HP 50 Duty CONTINUOUS TYPE TDS
KW 37
Frame 326T Serv. Factor 1.15 Phase 3
Max Amb 40 Design B Code G
Insul Class F Protection NOT Therm.Prot.
Eff 100% 93 Eff 75% PF 81.5
UL NONE CSA Yes Bearing OPE 6311
CC Number CC004A CE Yes Bearing PE 6312
Load Type Inverter Type Speed Range NONE
--------------------------------------------------------------------------------
Motor Wt. 515 LB Enclosure DP Lubrication STANDARD
Nameplate 92117-A-X-CDLM-B-A-X Mounting RIGID Rotation REV
Assembly Shaft Dia. Ext. Diag. A-EE7358-LN
Cust Part No Outline B-SS200078LN-1512 Ext. Diag2
Packaging B Outline Dash No Winding K2864249
Carton Label GROUP: 10
Iris Paint RED ENAMEL Test Card
--------------------------------------------------------------------------------
Form Factor RMS Amps Const Torque Speed Range
Torque Peak
AB Code Peak@DegC
Resistance
Connection
--------------------------------------------------------------------------------
Rework Status Rework TYPE
--------------------------------------------------------------------------------
Hazardous Loc NONE Brake Motors
Explosion Proof Temp Op Code FORCE
Class GROUP: VDC
Class GROUP: ADC
Brake Coil OHMs @25 C
Performance
Torque UOM Inertia (WK²)
Torque
CURRENT (amps)
Efficiency (%)
PowerFactor
Load Curve Data @60/50 Hz, 460 Volts, 50 Horsepower
Load Amps KW RPM Torque Eff PF Rise By Resis Frame Rise
0.0 24.5 1.0 1800 0.0 0.0 3.5 0.0 -
0.25 28.5 10.2 1792 36.5 91.7 45.0 0.0 -
0.5 37.0 20.0 1785 73.5 93.6 67.0 0.0 -
0.75 48.5 30.0 1778 112.0 93.6 77.0 0.0 -
1.0 61.5 40.0 1770 148.0 93.0 81.5 45.0 -
1.15 70.0 46.2 1765 171.0 93.0 82.5 60.0 -
1.25 76.5 50.5 1760 186.0 92.4 83.0 0.0 -