Industrial Motors
Couldn't load pickup availability
X038, 1/2 Hp, 460, 48Y FR, 1075/2 Rpm, Open Air Over, Extended Thru-Bolt, Fan Blower-Direct Drive, PSC, 48A11O1874.
Engineering Data
Output HP:0.50 Hp
Output KW:0.37 kW
Frequency:60 Hz
Voltage:460 V
Current:1.6 A
Speed:1075 rpm
Service Factor:1
Phase:1
Efficiency:62.6 %
Power Factor:85.1
Duty:Continous
Insulation Class:B
Design Code:2VT
KVA Code:D
Frame:48Y
Enclosure:Open Air Over
Thermal Protection:Automatic Lock Rotor Only
Ambient Temperature:40 °C
Drive End Bearing Size:6203
Opp Drive End Bearing Size:6203
UL:Recognized
CSA:Y
CE:NIP Code:01
Technical Specifications
Electrical Type:Permanent Split Capacitor
Starting Method:Across The Line
Poles:6
Rotation:Selective Counterclockwise
Mounting:Round
Motor Orientation:Horizontal
Drive End Bearing:Ball
Opp Drive End Bearing:Ball
Frame Material:Rolled Steel
Shaft Type:Single Special Extension
Overall Length:12.19 in
Frame Length:4.75 in
Shaft Diameter:0.500 in
Shaft Extension:6.06 in