LM30100, 40 HP, 3600 RPM, 284T FR, DP, 230/460 Vac, 3 PH, Rigid Base, Hydraulic Elevator Duty.
Engineering Data
Volts 230 Volts 460 Volts 230/460
F.L. Amps 72 F.L. Amps 36 F.L. Amps 97/48.5
S. F Amps S. F Amps S. F Amps
RPM 3600 Hertz 60/60
HP 30 Duty 80/120 STARTS/HOUR TYPE TDS
KW 22.4
Frame 284T Serv. Factor 1.0 Phase 3
Max Amb 40 Design VERIFY Code C
Insul Class F Protection NOT Therm.Prot.
Eff 100% 91 Eff 75% PF 85.5
UL V-INS, CONST UL REC CSA Yes Bearing OPE 210
CC Number EXEMPT CE Yes Bearing PE 311
Load Type Inverter Type Speed Range NONE
Motor Wt. 279 LB Enclosure DP Lubrication VERIFY
Nameplate 92117-R-X-BCD-B-A-X Mounting RIGID Rotation REV
Assembly Shaft Dia. Ext. Diag. A-EE7358-LN
Cust Part No Outline B-SS200030LN-1275 Ext. Diag2
Packaging B Outline Dash No Winding K256294
Carton Label GROUP : 6
Iris Paint GRAY - LINCOLN Test Card
Form Factor RMS Amps Const Torque Speed Range
Torque Peak
AB Code Peak@DegC
Resistance
Connection
Rework Status Rework TYPE
Hazardous Loc NONE Brake Motors
Explosion Proof Temp Op Code FORCE
Class GROUP : VDC
Class GROUP : ADC
Brake Coil OHMs @25 C
Performance
Torque UOM Inertia (WK²)
Torque
CURRENT (amps)
Efficiency (%)
PowerFactor
Load Curve Data @60/60 Hz , 460 Volts , 30 Horsepower
Load Amps KW2 RPM Torque EFF PF Rise By Resis Frame Rise
0.0 10.5 1.0 3600 0.0 0.0 11.0 0.0 -
0.25 14.0 6.0 3585 11.0 90.0 56.0 0.0 -
0.5 20.0 12.0 3570 22.0 91.7 76.5 0.0 -
0.75 27.0 18.0 3550 33.5 91.7 84.0 0.0 -
1.0 36.0 24.5 3530 44.5 91.0 85.5 40.0 -
1.15 40.0 27.0 3520 50.0 91.0 85.5 50.0 -
1.25 45.0 31.0 3505 56.0 90.0 86.5 60.0 -