Industrial Motors
Couldn't load pickup availability
REPLACED BY 199020.00
Engineering Data
Volts 208-230 Volts 460 Volts 190/380
F.L. Amps 56.5-52 F.L. Amps 26 F.L. Amps 49/24.5
S. F Amps 64-59 S. F Amps 29.5 S. F Amps 55/27.5
--------------------------------------------------------------------------------
RPM 1200 Hertz 60/50
HP 20 Duty CONTINUOUS TYPE TF
KW 14.9
Frame 286T Serv. Factor 1.15 Phase 3
Max Amb 40 Design B Code F
Insul Class F Protection NOT Therm.Prot.
Eff 100% 91.7 Eff 75% PF 77
UL Y-(LEESON UL REC) CSA Yes Bearing OPE 6210
CC Number CC005A CE No Bearing PE 6311
Load Type Inverter Type Speed Range NONE
--------------------------------------------------------------------------------
Motor Wt. 500 LB Enclosure TEFC Lubrication STANDARD
Nameplate 93405-L-N-ABDEF-A-B Mounting RIGID Rotation REV
Assembly Shaft Dia. Ext. Diag. A-EE7308AA-LE
Cust Part No Outline B-SS620245 Ext. Diag2
Packaging F Outline Dash No Winding CHT28660001
Carton Label GROUP: 1
Iris Paint GRAY ENAMEL Test Card
--------------------------------------------------------------------------------
Form Factor RMS Amps Const Torque Speed Range
Torque Peak
AB Code Peak@DegC
Resistance
Connection
--------------------------------------------------------------------------------
Rework Status Rework TYPE
--------------------------------------------------------------------------------
Hazardous Loc NONE Brake Motors
Explosion Proof Temp Op Code FORCE
Class GROUP: VDC
Class GROUP: ADC
Brake Coil OHMs @25 C
Performance
Torque UOM Inertia (WK²)
Torque
CURRENT (amps)
Efficiency (%)
PowerFactor
Load Curve Data @60/50 Hz, 460 Volts, 20 Horsepower
Load Amps KW RPM Torque Eff PF Rise By Resis Frame Rise
0.0 12.6 0.6 1200 0.0 0.0 4.5 0.0 -
0.25 13.9 4.3 1195 22.0 84.0 38.0 0.0 -
0.5 16.9 8.2 1190 44.0 90.2 60.0 0.0 -
0.75 21.0 12.2 1182 66.5 91.7 71.0 0.0 -
1.0 26.0 16.3 1175 89.0 91.7 77.0 65.0 -
1.15 29.5 18.8 1172 102.0 91.0 78.5 85.0 -
1.25 32.0 20.5 1170 112.0 90.2 79.0 105.0